R-SR-1309 & R-SR-1310
2
2-3
Introduction
10-04-2017
The liability of REVITAL BATHROOM COM-
FORT is explicitly limited to the warranty obli-
gations described herein. Any other claim for
damages not meeting the warranty obligations
of REVITAL BATHROOM COMFORT will be
excluded.
With the exception of the general applicable
legal regulations regarding liability, including
product liability, it will in no case be possible to
claim for any consequential damages resulting
from the damages occurring to the materials
provided by REVITAL BATHROOM COM-
FORT or work that has been done that was au-
thorised by REVITAL BATHROOM COM-
FORT.
These warranty conditions are subject to the
general delivery and payment conditions, as
these have been filed by REVITAL BATH-
ROOM COMFORT under number 8107417,
with the Chamber of Commerce in Enschede,
the Netherlands. A copy of these will be sent
free of charge to the purchaser or their suc-
cessor upon first request.
Revital Bathroom Comfort
is a brand name of
:
Revital B.V., Enter, the Netherlands
Electrical installation
Connection of the electrical parts may only be
realised by an officially recognised electrical
engineer. This device is classified in Safety
Class 1 and has to have permanent connec-
tions to the mains. The plug must have con-
tacts with a thickness of 3 mm. During the in-
stallation, the installer has to strictly observe
the installation instructions of the local electrici-
ty companies, as well as the stipulations in DIN
57100 or VDE 0100-701:2002. The supply ca-
bles (sheathed cable H05W-F3 G1,5) have to
be led via an earthing switch (25A 230V output
current = 30 mA) and all poles have to be pro-
tected by an automatic fuse. Any live parts,
with the exception of safety low-voltage parts,
may not be accessible to persons inside the
shower cubicle. The steam generator may only
be opened by a person authorised by REVI-
TAL BATHROOM COMFORT. Make sure the
required mass is available and connect the
steam-shower cubicle to it.
Water connection
The supply-water and discharge-water connec-
tions may only be realised by an officially rec-
ognised engineer.
The water pressure
may not exceed 4 bar.
After installation of the steam-shower
cubicle, all electrical and water
connections, including the premounted
connections, must be inspected to
make sure the connections have been
made correctly and to make sure there
are no signs of leakage.
Technical data of the steam generator
Water volume
Approx. 0.6 litres
Power
3.2 kW
Voltage
230 V
Frequency
50 Hz
Input current
Max. 14 A
Recommended fuse
16 A
Temperature steam bath Approx. 25-60°C
Steam duration
Approx. 1-50 mi-
nutes
Heating-up time
Approx. 8-10 mi-
nutes