13
Technical documentation I Vision Vent 2 Hood I Transport and installation
TraNSporT aNd
iNSTallaTioN
1. traNSpOrtINg the applIaNce
1. 1 Instructions for transporting the
appliance
Take all possible care when transporting the appliance. Take
particular care during transport to ensure that the appliance is not
damaged.
wheN receIVINg the prOduct:
•
immediately check the number of items against the accompanying
•
documents (delivery note, invoice, freight note)
•
inspect the condition of the packaging and equipment.
If there IS aNy damage, dO the fOllOwINg:
•
request a “damage report“ on the spot
•
take detailed photos of the damage.
•
if the damage appears to be greater than CZk 10,000, we
recommend consulting an insurance assessor
•
have the damage report confirmed by the driver, transport
company or airport employee.
The packaging will not protect the appliance from impact or
pressure from sharp or blunt objects.
after unpacking the appliance, check to see that the delivery
is complete according to the delivery slip, and remove all
documents and packing material from inside the appliance.
2. waSte dISpOSal
under act 477/2001 (94/62/EC), retigo s.r.o. is authorized to use
the green dot symbol, which means that the price of the product
includes costs associated with disposing of the packing material.
according to Section 10 of act 185/2001 Coll. on refuse, follow the
instructions below:
2. 1 disposing of packaging
Take the cardboard for recycling. place the protective film and
polystyrene supports into a recycling collection container for
plastics.
2. 2. disposing of the appliance after the end
of its useful life
The appliance can then be taken out for recycling.
3. INStallINg the applIaNce
operate the appliance only in perfect condition. do not remove any
safety equipment such as covers etc. do not modify the appliance
in any way.
3. 1 preparing the appliance for installation
•
before installing the hood, disconnect the appliance from the
power supply.
•
always install the hood in accordance with the regulations and
standards applicable in your country.
•
The hood will only work correctly if installed on an appliance with
the following software versions:
blue Vision
– version 2.28 or higher
orange Vision – version 3.49 or higher
•
unpack the hood carefully from the transport packaging and
remove the protective cover.
•
The hood is made for operation on an appliance with a right
opening door. if it is installed on an appliance with a left opening
door, the hood’s front cover should be replaced. The cover forms
part of the delivery.
•
The hood must be modified if it is to be mounted onto
a combination of two appliances. To modify the hood, follow the
"Set for combination with hood", article aa11-9908.
3. 2 fitting the hood onto the appliance
•
remove the side cover of the appliance onto which the hood is
to be installed. unscrew the bolts of the cover using a screwdriver
and a No. 8 spanner, see fig. 1.
figure 1: 0610 hood for appliance size 611