background image

www.zephyronline.com

Guide 

d’utilisation, 

d’entretien 

et 

d’inst

allation

Use, 

C

are, 

and 

Inst

allation 

Guide

Model number:

Numéro de modèle: ____________________________________

Número de modelo:

Serial number:

Numéro de série: _____________________________________

Número de serie:

Date of Purchase:

Date d’achat:

_____________________________________

Fecha de compra:

Sales Dealer:

Détaillant:

_____________________________________

Distribuidorr:

LI2Q9A  1005

 rev:1

READ AND SAVE THESE INSTRUCTIONS

Guía 

de 

inst

alación, 

uso 

mantenimiento

LISEZ CES INSTRUCTIONS ET  CONSERVEZ-LES

LEA Y GUARDE ESTAS INSTRUCCIONES

Optica Island

EOT-E42ASX

EOT-E48ASX

Summary of Contents for Optica Island EOT-E42ASX

Page 1: ...e _____________________________________ N mero de serie Date of Purchase Date d achat _____________________________________ Fecha de compra Sales Dealer D taillant ____________________________________...

Page 2: ...eave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring...

Page 3: ...not supplied 6 Dimensions and clearances 7 Installation Instructions 8 Venting methods 8 Preparation 8 Installation Ductwork Calculation Sheet 9 Installation 10 Electrical connection 12 Description o...

Page 4: ...Use This Hood With Any External Solid State Speed Control Device WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking a...

Page 5: ...l local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed m...

Page 6: ...t PARTS NOT SUPPLIED Duct conduit and all tools required for installation Ductless recirculating kit to be used only in the Ductless recirculating version includes charcoal filter charcoal filter supp...

Page 7: ...online com Dimensions and clearances 42 48 14 min 31 10 16 max 49 min 30 8 16 max 43 14 16 12 3 16 27 8 16 1 26 4 16 Ductless recirculating version ONLY Note if necessary order the proper duct cover e...

Page 8: ...um Duct Size Ducting Ductless version 8 Round Pipe PREPARATION Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Fitting...

Page 9: ...wall cap with damper 6 Round roof cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Rou...

Page 10: ...ed on ceiling to position the mounting template Note location of hood front that indicated with a printed arrow side and mounting holes indicated on template Note Remember that printed arrow on templa...

Page 11: ...x 4 screws 4 1 2 3 6 7 8 FRONT 4 For non vented recirculating installations ONLY Fix the deflector on the chimney structure 5 Note disregard this step if is intended to install a remote ventilator Pu...

Page 12: ...ite and green according to the National Electrical Code and local codes and ordinances in 1 2 conduit from service panel to junction box J Box cover Conduit Connect black wire from service panel to bl...

Page 13: ...e of top duct covers sections squere slots and fix each other with 6 screws 3 per side Rectangular slots Plan diagram top sections Nut top sections Chimney Structure 13 Install top duct covers assembl...

Page 14: ...assembly rear bottom duct covers section Plan diagram top view rear bottom duct covers section snap into place 15 Fit the front bottom duct covers section and fix both sections with 8 screws each oth...

Page 15: ...to make sure they are secure in their sockets Turn power on in service panel Check lights and blower operation per Care Use section of this manual If range hood does not operate Check that the circuit...

Page 16: ...It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cookin...

Page 17: ...d or in the dish washer which must be set to a low temperature and a short cycle When washed in a dish washer the grease filter may discolour slightly but this does not affect its filtering capacity T...

Page 18: ...g area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter is loos...

Page 19: ...nce misuse abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connect...

Page 20: ...on Part halogen bulb 12V 20 W metal filter Part Description Part Ductless recirculating kit charcoal replacement filter duct cover extension kit internal blower 600 cfm in line blower 1100 cfm ZRC 00A...

Page 21: ...21 www zephyronline com...

Page 22: ...22...