background image

Cod:0103086060

90cm T-Shaped Island Hood

ICHT02101

 - Stainless Steel

Summary of Contents for ICHT02101

Page 1: ...Cod 0103086060 90cm T Shaped Island Hood ICHT02101 Stainless Steel...

Page 2: ...ur Guarantee In the unlikely event that you experience a problem with your Hood you can rest assured that you are fully protected against the cost of repairs for the first 24 months Please note that a...

Page 3: ...y EMC IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN AJ CORDANCE WITH EC DIRECTIVE 2002 96 EC At the end of its working life the product must be taken to a special local authority waste...

Page 4: ...actor press and hold the key for 2 seconds The clock display will flash Use or keys to set the hour press key to set after which you can adjust the minutes Once set press key to confirm Please note th...

Page 5: ...you should remove and clean the grease filter with hot soapy water You can also wash the grease filter in a dishwasher ensuring that you place it in an upright position to prevent damage from other it...

Page 6: ...l filters included to remove odors Attention The range hood leaving factory is with charcoal filters installed For ducting discharge please remove charcoal filters To ensure best performance of your r...

Page 7: ...illumination Extended use of the light can reduce the life span of the lights Lights replacement is not covered by the guarantee Remove the lamp by flat head screwdriver Fig 4 I Check with your local...

Page 8: ...ows The wire which is coloured green and yellow must be connected to the terminal marked E Earth or coloured green The wire which is coloured blue must be connected to the terminal marked N Neutral or...

Page 9: ...9 INSTALLATION Fig 5 To accommodate di erent user requirements the product can be installed in 2 ways see Fig 5 and Fig 6 Fig 6 700 1010mm 820 1010mm...

Page 10: ...NOT BE COVERED BY THE WARRANTY Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 Fix damper on the unit by 4 pieces ST4X10 screws Tools required Screw 4 pieces plastic expanding plugs on ceiling as installation...

Page 11: ...during installation by using a non abrasive stainless steel cleaner Always follow the instructions given with the cleaner being used Fig 14 Fig 15 Put the outer chimney on the unit Put the inner chim...

Page 12: ...est WBEP 89 3 360 7 Lux 0 4 0 8 0 49 66 L W r e w o p g n i t h g i l l a n i m o N Average illumination of the lighting system on the cooking surface EMiddle 180 Measured power consumption in standby...

Page 13: ...modification or inexpert repair Cost of Call out where a fault cannot be found with the appliance Cost of Call out for work covering routine maintenance such as but not exclusively cleaning of filter...

Page 14: ...you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed informatio...

Reviews: