Technical documentation I Vision Vent 2 Hood I Transport and installation
5. electrIcal cONNectIONS fOr a 623
hOOd
The hood may be connected only to a normalized voltage network,
whose parameters match the data listed on the hood’s nameplate.
The hood must be protected by a fuse of up to 16a.
at the back of the hood there is an m6 bolt (6), which is for protective
couplings, see fig. 14. Connect it to a suitable cable and make the
protective couplings.
5. 1. connecting the control parts
at the back of the hood, there is a plastic distributor (4), from
which the controlling uTp cable (2) emerges, at the end of which is
connector rJ-45 (see fig. 14).
run the uTp cable (2) directly downwards to the pierced flanges
(3) in the back left corner of the base of the appliance (see fig. 14).
figure 14: back of 623 hood
after breaking through the flange marked with the number “2”,
insert cable gland m20x1,5 into it, thread the uTp cable through the
gland and fasten it securely (see fig. 15).
figure 15: location of the flanges on the base of an appliance of
size 623
run the uTp cable (2) over the upper edge of the electrical board (1)
and down towards the relay panel (3), see fig. 16.
figure 16: route of uTp cable inside appliance 623
fit the end of the uTp cable (2) into rJ-45 port (1) marked X4 or X5
on the relay panel (3) (see. fig. 17).