2.10 Setting Switches
2.10.1 Setting the Jumper on the Emulation Probe
Figure 2.16 shows the location of jumper switches on the R0E521000EPBM0 board and their factory-settings.
Figure 2.16 Jumper switches on the R0E521000EPBM0
Table 2.2 Setting jumper switches on the R0E521000EPBM0
Switch No.
Switch name
How to set
Description
JP1
POWER
selection
jumper
Settings of this jumper need to be changed according to the power
supply voltage and power supply condition of the user system. The
internal power supply is supplied to the evaluation MCU in factory
setting.
For details, refer to “2.10.2 “Setting the POWER Selection Jumper”
(page 39).
JP2
RESET pin
pullup jumper
This jumper pulls the user system’s RESET pin high with 510 k
Ω
.
Although settings of this jumper do not normally need to be
changed,
if the 510 k
Ω
pullup presents a problem when the user
system is connected, the board may be used without this resistor
pullup.
CAUTION
Note on Changing Jumper Settings:
z
Always shut OFF the emulator before changing the setting of the jumper switches, and connecting the cable.
Otherwise the internal circuit may cause a break.
J1