R0E521000EPB00 User’s Manual
5. Troubleshooting
REJ10J0844-0400 Rev.4.00 October 16, 2007
Page 80 of 88
5. Troubleshooting
This chapter describes how to troubleshoot when this product does not work properly.
5.1 Flowchart to Remedy the Troubles
Figure 5.1 shows the flowchart to remedy the troubles from when the emulator is activated until the emulator debugger starts
up. At first, check this when the user system is disconnected. After confirming that there are no problems, then check this
when the user system is connected. For the latest FAQs visit the Renesas Tools Homepage.
http://www.renesas.com/tools
Turning on emulator
Upper panel LED
of emulator
1 . Check connection of the power supply cable.
See
“
2. 5 Connecting the Power Supply for the Emulator
”
( page 24).
2 . Check that the power is properly supplied to the user system .
See
“
2. 6 Turning ON the Power
”
( page 25).
Init dialog box of emulator
debugger displayed
1 . Check the operating environment etc. of the emulator
debugger.
See the user
‘
s manual of the emulator debugger.
2 . Reinstall the emulator debugger .
MCU setting dialog box of
emulator debugger
See
“
5.2. 2 MCU Setting Dialog Box Does Not Appear at
Debugger Startup
”
( page 82).
Editor (source) window of emulator
debugger displayed
See
“
5.2. 3 Errors Occur at Debugger Startup
”
( page 83).
Emulator debugger startup completed
Not normal
Not normal/ Error displayed
Not normal/ Error displayed
Error displayed
3 . Redownload the firmware .
See
“
2. 7 Downloading Firmware
”
( page 26).
Figure 5.1 Flowchart to remedy the troubles