![Rena XPS-80 User Manual Download Page 55](http://html1.mh-extra.com/html/rena/xps-80/xps-80_user-manual_1439477055.webp)
RENA XPS-80/90
User Guide
5-26
Mutual calibration of the print units (DIST. CORR)
Assuming that the previous cali-
bration has been performed, a mu-
tual misalignment between the
print units can now be compen-
sated.
A calibration must be performed
when the print image shows a
misalignment D.
•
Press the
start
key to go to off-
line mode (if you are on-line).
•
Press the
prog
key.
•
Press the
next
key repeatedly in programming mode until the
following main menu feature appears.
•
Press the
enter
key to select this menu feature.
•
•
•
Set the correct value as required with the
prev
or
next
key.
Value range:
+48 to –48, one increment = 0.08mm (= 1/300“)
Positive values shift the print image of a print unit 2 to the left,
negative values to the right.
•
Note:
While in this mode, the
pap
key can be pressed to per-
form an alignment test pattern.
Testprint DA62
Rena Informati
GmbH & Co. KG
Bahnhofplatz 3
82041 Oberhach
Linie10, Unit
Linie11, Unit
Linie12, Unit
Linie13, Unit
Linie14, Unit
Linie15, Unit
Linie16, Unit
Linie17, Unit
Linie18, Unit
D
Test print DDP
Testprint XPS-90/80
“The Envelope Imagin
RENA Systems, Inc.
136 Greentree Rd, St
P.O. Box 1069
Oaks PA 19456-1069
DIST. CORR.1-2: 0
<pap> = Test Pattern