RENA XPS-80/90
User Guide
5-24
Mutual calibration of the cartridges (CARTRIDGE
CORR)
This type of calibration may become necessary because no print
unit can be manufactured completely without tolerances. Minor
deviations due to manufacturing tolerances, as well as the toler-
ances of the ink cartridge, can be compensated by the software in
the printer.
C1
C2
C3
+ Werte
- Werte
B
C
The need for calibration becomes evident when the bar to the left
of the test print shows a misalignment B and/or a misalignment C.
•
Press the
start
key to go to off-line mode (if you are on-line).
•
Press the
prog
key.
•
Press the
prev
key repeatedly until the main menu feature
“CARTRIDGE CORR“ appears.
•
Press the
enter
key to select this menu feature.
•
•
•
Press the
prev
or
next
key to select the relevant print unit (U1,
U2 or all).
Selection options:
all
= both print unit, cartridge pairs are simultaneously adjusted.
U1
= adjust carriage pairs within print unit U1
-Value
+Value
CARTRIDGE CORR: all
<pap> = Test Pattern