Markers

Code no.

Description

BOILER BODY

1

8377-8911

Boiler body - 8 sections

1

8377-8913

Boiler body - 10 sections

1

8377-8915

Boiler body - 12 sections

1

8377-8917

Boiler body - 14 sections

2

8377-5500

Lateral section right

3

8377-5501

Lateral section left

4

8377-5502

Intermediate section

5

8377-0547

Painted nipple  

6

8377-8920

Complete closing plate

7

8377-5503

Assembly rod M8 - LG580

7

8377-5504

Assembly rod M8 - LG660

7

8377-5505

Assembly rod M8 - LG750

7

8377-5506

Assembly rod M8 - LG830

7

8377-5507

Assembly rod M8 - LG910

7

8377-5508

Assembly rod M8 - LG1000

7

8377-5509

Assembly rod M8 - LG1080

7

8377-5510

Assembly rod M8 - LG1170

8

8377-8726

Complete assembly cross-bar

9

9536-5611

Sensor tube 1/2"

10

9536-5613

Contact spring for thimble tube

11

9495-0249

Plug nr.290 1" 1/2

12

9504-6127

Adhesive thermocord Ø10

13

8377-8905

Complete base - 8 sections

13

8377-8906

Complete base - 10 sections

13

8377-8907

Complete base - 12 sections

13

8377-8908

Complete base - 14 sections

14

9755-0728

Insulation under burner - 8 sections

14

9755-0730

Insulation under burner - 10 sections

14

9755-0732

Insulation under burner - 12 sections

14

9755-0734

Insulation under burner - 14 sections

15

9755-0718

Rear insulation - 8 sections

15

9755-0720

Rear insulation - 10 sections

15

9755-0722

Rear insulation - 12 sections

15

9755-0724

Rear insulation - 14 sections

16

9754-9668

Outlet pipe

17

9754-9660

Return pipe - 8 sections

17

9754-9670

Return pipe - 10 sections

17

9754-9671

Return pipe - 12 sections

17

9754-9672

Return pipe - 14 sections

18

9755-0189

Flange gasket

19

8377-4091

Insulation, outlet pipe

20

9696-0228

Brush 22 x 11 L500

21

8800-8966

Box of mastic (1 kg)

22

9430-5027

Putty for nipple (300g)

23

9428-5066

Paste PERMABOND A1044

24

8377-5534

Accessories bag

DRAUGHT DIVERTER

25

8502-8640

Draught diverter complete - 8 sections

25

8502-8642

Draught diverter complete - 10 sections

25

8502-8644

Draught diverter complete - 12 sections

25

8502-8646

Draught diverter complete - 14 sections

8502-1558

Painted draught diverter - 8 sections

8502-1560

Painted draught diverter - 10 sections

8502-1562

Painted draught diverter - 12 sections

8502-1564

Painted draught diverter - 14 sections

26

8502-5501

Inspection hatch - 8 sections

26

8502-5503

Inspection hatch - 10 sections

26

8502-5505

Inspection hatch - 12 sections

26

8502-5507

Inspection hatch - 14 sections

27

8377-5533

Plug for draught diverter

28

8377-8708

Screw bag

29

9758-1497

Nozzle Ø 180

29

8116-8076

Nozzle Ø 200

29

8377-8146

Nozzle Ø 225

30

8377-8226

Adaptor ring Ø225 to 220

31

9536-3357

Limiting thermostat (fitted to 8 section 
boiler, option RD19 for 10 to 14 sections)

32

8375-8077

Mounting square

33

8502-4917

Electric circuit

GAS LINE

40

200003830

Complete gas circuit - 8 sections

40

200003831

Complete gas circuit - 10 sections

40

300003832

Complete gas circuit - 12 sections

40

300003833

Complete gas circuit - 14 sections

41

8502-5571

Burner support - 8 sections

41

8502-5573

Burner support - 10 sections

41

8502-5575

Burner support - 12 sections

41

8502-5577

Burner support - 14 sections

42

8502-5557

FURIGAS interignition burner (under 
ignition burner)

43

8368-8595

FURIGAS burner

44

9536-0220

Pressure socket

45

8502-5600

Insulation, burner drawer - 8 sections

Markers

Code no.

Description

Summary of Contents for GAS 360 S

Page 1: ...Supplied By www heating spares co Tel 0161 620 6677 Remeha Gas 360 S Gas fired boilers Technical instructions English 20 07 05...

Page 2: ...n 10 1 Furnace operation equipped with safety box S4565 BF 1161 10 Adapting to another gas 14 1 Changing the burner nozzles 14 2 Changing the ignition burner injector 14 3 Setting the nozzle pressure...

Page 3: ...3 3 of the directive 97 23 EC it is certified by compliance with the directives 90 396 EC 92 42 EC 73 23 EC and 89 336 EC 1 Regulations It is in any case imperative to conform to the local regulations...

Page 4: ...is CE approved under the following number 0085AU0115 The boilers are in compliance with the EC directives Royal Decree dated 8th January 2004 90 396 EEC Gas Appliance Directive Reference Standard EN 2...

Page 5: ...ete ignition burner a Ignition electrode This ensures ignition burner ignition using a high voltage spark b Ionisation probe It detects flame presence on the ignition burner by flame ionisation 6 Safe...

Page 6: ...d the heating pump don t operate If the boiler is fitted with a control unit both buttons must be left on the Winter position 3 Main ON OFF switch 4 Location for hour run meter for the first and secon...

Page 7: ...45 54 54 2nd stage kW 63 81 99 117 Power input 1st stage kW 39 4 49 1 58 8 58 8 2nd stage kW 68 9 88 4 107 8 127 2 Number of sections Part 8 10 12 14 Mass flue gas flow rate 1 2 1st stage Kg h 140 16...

Page 8: ...20 6677 8 Remeha Gas 360 S 20 07 05 300005180 001 A 5 Identification plate The rating plate affixed to the front panel during assembly provides the exact identification of the boiler and indicates its...

Page 9: ...A 6 Main dimensions Connection for safety valves Rp 1 Heating outlet R 1 1 2 Heating return R 1 1 2 Draining Rp 3 4 Gas inlet R 1 Boiler Gas 360 S 8 10 12 14 A mm 946 1113 1280 1447 B mm 952 1007 1007...

Page 10: ...e valve VP2 opens Behaviour in abnormal conditions If the flame is not detected before the end of the safety time ts the safety control box goes into safety lockout and the safety lockout warning ligh...

Page 11: ...sformer TCH1 Boiler thermostat 1 Speed TCH2 Boiler thermostat 2 Speed VA Safety lockout warning light VBa Ignition burner valve VP1 Main burner valve 1 Speed VP2 Main burner valve 2 Speed t3n Flame st...

Page 12: ...ntrol valve 2 Safety solenoid valve 3 Gas inlet 4 Safety valve quality level B 5 Gas filter 6 Valve 7 Pressure adjustment screw 8 Pressure socket 9 Membrane 10 Main valve quality level D 11 Outlet to...

Page 13: ...socket 3 Output pressure socket 4 Safety solenoid valve 5 Lower regulation chamber 6 Controlled regulation flap 7 Distribution channel 8 Solenoid control valve 9 Threshold ignition system 10 Lower mem...

Page 14: ...m spanner and fit the new nozzles with their new seals First tighten the nozzles by hand and carefully lock them using a spanner Carry out a leak tightness check 2 Changing the ignition burner injecto...

Page 15: ...essure outlet on the manifold Turn the boiler on Set the boiler thermostats to maximum Unscrew the protection cap on each valve Set the pressure on the left and right valves as shown in the table in t...

Page 16: ...rewdriver In the factory it is set to maximum To modify this setting it necessary first to remove the protection using a screwdriver 1 4 turn The progressivity of the left valve 2nd stage is always se...

Page 17: ...677 17 Remeha Gas 360 S 20 07 05 300005180 001 A 4 1 Operation of the progressivity screw setting A Downstream pressure mbar B Time s 5 Attaching the label Affix the label which indicates for which ty...

Page 18: ...bar Boiler type Gas 360 S 8 10 12 14 Nozzle pressure Natural gas H mbar 14 14 14 14 Propane mbar 36 36 36 36 Start up pressure Natural gas H mbar 11 11 11 11 Propane mbar 10 10 10 10 Nozzle Number of...

Page 19: ...e socket located on the manifold Check that the nozzle pressure and the start up pressure match the pressures given in the relevant chapter Pressure settings and calibrated nozzle markings If necessar...

Page 20: ...dy must be checked once a year If it is necessary to sweep the boiler remove the burner drawer to prevent deposits and soot blocking the orifices in the gas trains With the burner out Take the column...

Page 21: ...lectrode gap 9 and the position of the flame diffuser 17 in terms of the sizes indicated on the drawing required in the event of heater malfunction After reassembly check for leak tightness 1 3 Painte...

Page 22: ...into standby burner cut and the alarm indicator flashes Anti blowback thermostat cut Check for adequate draw on the chimney connection Press the reset button on the safety control box Check that the d...

Page 23: ...Heater too hot or too cold for requirements 3 position switch on position Check the position of the 3 position switch Wrong setting for the heater thermostat Set the heater thermostat if the heater ha...

Page 24: ...heating spares co Tel 0161 620 6677 Spare parts Gas 360 S The code number on the list next to the required piece must be stated when ordering replacement parts 20 07 05 300005180 002 A Boiler body Dr...

Page 25: ...Supplied By www heating spares co Tel 0161 620 6677 25 Remeha Gas 360 S 20 07 05 300005180 001 A Gas line 8 10 12 sections...

Page 26: ...Supplied By www heating spares co Tel 0161 620 6677 26 Remeha Gas 360 S 20 07 05 300005180 001 A Gas line 14 sections...

Page 27: ...Supplied By www heating spares co Tel 0161 620 6677 27 20 07 05 300005180 001 A Remeha Gas 360 S Control panel K Control panel K Components...

Page 28: ...Supplied By www heating spares co Tel 0161 620 6677 28 Remeha Gas 360 S 20 07 05 300005180 001 A Metal casing for control panel K...

Page 29: ...Supplied By www heating spares co Tel 0161 620 6677 29 20 07 05 300005180 001 A Remeha Gas 360 S Boiler body insulation...

Page 30: ...Supplied By www heating spares co Tel 0161 620 6677 30 Remeha Gas 360 S 20 07 05 300005180 001 A Cladding...

Page 31: ...pipe 12 sections 17 9754 9672 Return pipe 14 sections 18 9755 0189 Flange gasket 19 8377 4091 Insulation outlet pipe 20 9696 0228 Brush 22 x 11 L500 21 8800 8966 Box of mastic 1 kg 22 9430 5027 Putty...

Page 32: ...8502 8108 Flame non return plate 8 sections 74 8377 8188 Flame non return plate 10 sections 74 8377 8190 Flame non return plate 12 sections 74 8377 8192 Flame non return plate 14 sections 75 8800 8961...

Page 33: ...177 200003526 Complete upper front panel 8 sections 177 200003527 Complete upper front panel 10 sections 177 200003528 Complete upper front panel 12 sections 177 200003529 Complete upper front panel 1...

Page 34: ...Supplied By www heating spares co Tel 0161 620 6677 Remeha Gas 360 S 20 07 05 300005180 001 A...

Page 35: ...Supplied By www heating spares co Tel 0161 620 6677 Remeha Gas 360 S 20 07 05 300005180 001 A...

Page 36: ...ra 55 59 08005 BARCELONA Tel 34 3 3000204 Fax 34 3 3009558 E Cuatrocesa S A c Sor Angela de La Cruz 10 1 Oficina C 28020 MADRID Tel 34 91 658 18 88 Fax 34 91 658 30 77 E D A C S A Tom s A Edison 29 Po...

Reviews: