Supplied By www.heating spares.co Tel. 0161 620 6677
7
Remeha Gas 360 S
20/07/05 - 300005180-001-A
4 Technical characteristics
The boilers can operate on natural gas H/E or propane.
Conversion to propane is done following the operations described in
the chapter "Adaptation to another gas".
(1)
At nominal output (2nd stage)
(2)
Boiler temperature 80°C
(3)
Electrical output of the boiler only with no accessories
Conditions of use
- Maximum safety temperature: 110°C
- Maximum operating pressure: 6
bar
- Thermostat adjustable from 30 to 90°C
- Safety thermostat: 110°Put the insulation plate *1 under the burner
after unscrewing the self-tapping screw *2 pre-assembled to the
baseC
Boiler
Gas 360 S/
8
10
12
14
Useful efficiency
1st stage
kW
36
45
54
54
2nd stage
kW
63
81
99
117
Power input
1st stage
kW
39.4
49.1
58.8
58.8
2nd stage
kW
68.9
88.4
107.8
127.2
Number of sections
Part
8
10
12
14
Mass flue gas flow rate
(1) (2)
1st stage
Kg/h
140
166
199
199
2nd stage
138
177
216
255
Flue gas temperature Tf
(1) (2)
°C
135
135
135
135
CO
2
(Natural gas H)
(1)
%
7.4
7.4
7.4
7.4
Ionisation current
(1)
µA
3
3
3
3
Required depressurisation at the
nozzle
(1)
mbar
0.04
0.04
0.04
0.04
Minimum outlet temperature
°C
30
30
30
30
Maximum outlet temperature
°C
90
90
90
90
Maximum operating pressure
bar
6
6
6
6
Electrical connection
V/Hz
230/50
230/50
230/50
230/50
Electrical output
(3)
W
25
25
25
25
Gas connection
inch
R1
R1
R1
R1
Heating connection
inch
R 1 1/2
R1 1/2
R1 1/2
R1 1/2
Internal diameter flue gas nozzle
mm
180
200
200
225
Water resistance
(1)
∆
T = 10K
mbar
56
120
216
320
∆
T = 15K
25
53
96
142
∆
T = 20K
14
30
54
80
Water capacity*
l
l
32.6
39.8
47
54.2
Shipping weight
kg
257
305
357
408