Remeha Gas 360 S

20/07/05 - 300005180-001-A

45

8502-5602

Insulation, burner drawer - 10 sections

45

8502-5604

Insulation, burner drawer - 12 sections

45

8502-5606

Insulation, burner drawer - 14 sections

46

9754-9041

Gas inlet pipe - 8 sections

46

9754-9042

Gas inlet pipe - 10-12 sections

46

9754-9043

Gas inlet pipe - 14 sections

47

9754-9353

Connecting pipe

48

9501-3062

Green joint Ø 30 x 21 x 2

49

8502-4704

Valve 1st stage HONEYWELL CVI

50

9754-9889

Elbow flange LOVATO

51

9502-3306

Toric gasket 27.7 x 22.5 x 2.5

52

9755-0196

Gasket 27.2 x 16 x 3

53

8502-5578

Safety box HONEYWELL

54

9536-5259

Cover, safety control box

55

8502-4922

Panel circuit - safety control box

56

8502-4705

Valve 2nd stage HONEYWELL CVI - 8-12 
sections

57

8502-4923

Electric circuit Valve 2nd stage - 8-12 
sections

58

8502-4706

Valve 2nd stage HONEYWELL CVI - 14 
sections

59

9754-9839

Elbow flange LOVATO

60

9755-0178

Green joint Ø 30 x 21 x 2

61

9754-9231

Right flange 1/2"

62

9758-0632

Toric gasket  

63

8502-4901

Electric circuit Valve 2nd stage - 14 
sections

64

8368-4907

Earth wire

65

9536-9107

Diaphragm Ø6.5 24.3 x 1 - 8 sections

67

9501-3068

Green joint Ø 24 x 30 x 1.5

68

8502-8719

Complete ignition burner

69

8406-8092

Spacer

70

8502-5579

Ignition burner gas supply pipe

71

9758-0451

Wired ionisation sensor with elbow

72

9533-2802

Wired ignition plug

73

9501-3064

Green joint Ø 32 x 44 x 2

74

8502-8108

Flame non-return plate - 8 sections

74

8377-8188

Flame non-return plate - 10 sections

74

8377-8190

Flame non-return plate - 12 sections

74

8377-8192

Flame non-return plate - 14 sections

75

8800-8961

Glue 1000 (100 ml can)

76

8502-5516

Screw bag

77

8502-4925

Earth liaison wire

Markers

Code no.

Description

CONVERSION KITS

78

100003809

Propane conversion kit

78

100003840

Natural gas conversion kit H

CONTROL PANEL 

K

90

8502-8751

Control system

92

8502-5519

Fasteners

93

200003824

Front panel s Control panel front 
cover

94

9421-0705

Control panel front cover K

95

9536-5157

Flat thermometer

96

8500-0002

Thermostat adjustable from 30 to 90°C

97

8500-0032

Safety thermostat 110°C

98

9521-6281

Round green indicator

99

8555-5501

Setting  Pin

100

9532-5027

Green S/S bipolar switch

101

9532-5102

Reset switch

102

9532-5103

Test Switch STB

103

8500-0034

Bipolar switch

104

8500-0035

Bipolar switch

105

9534-0288

4A TS710/4A Circuit-breaker

106

8502-4921

Control panel harness K

107

8502-4913

Flue damper connector bridge

108

8377-4917

TAF connector bridge

109

8350-4805

Anti-parasite filter

110

8502-4925

Earth liaison wire

METAL CASING FOR 
CONTROL PANEL 

K

145

8502-5558

Protection cap

146

8502-8625

Card supports

147

8502-8778

Control panel bracket

148

8502-5560

Piano hinges (2 items)

149

8387-5556

Flap

BOILER BODY INSULATION

150

8377-8932

Complete insulation - 8 sections

150

8377-8934

Complete insulation - 10 sections

150

8377-8936

Complete insulation - 12 sections

150

8377-8938

Complete insulation - 14 sections

CLADDING

170

200003820

Cladding complete - 8 sections

Markers

Code no.

Description

Summary of Contents for GAS 360 S

Page 1: ...Supplied By www heating spares co Tel 0161 620 6677 Remeha Gas 360 S Gas fired boilers Technical instructions English 20 07 05...

Page 2: ...n 10 1 Furnace operation equipped with safety box S4565 BF 1161 10 Adapting to another gas 14 1 Changing the burner nozzles 14 2 Changing the ignition burner injector 14 3 Setting the nozzle pressure...

Page 3: ...3 3 of the directive 97 23 EC it is certified by compliance with the directives 90 396 EC 92 42 EC 73 23 EC and 89 336 EC 1 Regulations It is in any case imperative to conform to the local regulations...

Page 4: ...is CE approved under the following number 0085AU0115 The boilers are in compliance with the EC directives Royal Decree dated 8th January 2004 90 396 EEC Gas Appliance Directive Reference Standard EN 2...

Page 5: ...ete ignition burner a Ignition electrode This ensures ignition burner ignition using a high voltage spark b Ionisation probe It detects flame presence on the ignition burner by flame ionisation 6 Safe...

Page 6: ...d the heating pump don t operate If the boiler is fitted with a control unit both buttons must be left on the Winter position 3 Main ON OFF switch 4 Location for hour run meter for the first and secon...

Page 7: ...45 54 54 2nd stage kW 63 81 99 117 Power input 1st stage kW 39 4 49 1 58 8 58 8 2nd stage kW 68 9 88 4 107 8 127 2 Number of sections Part 8 10 12 14 Mass flue gas flow rate 1 2 1st stage Kg h 140 16...

Page 8: ...20 6677 8 Remeha Gas 360 S 20 07 05 300005180 001 A 5 Identification plate The rating plate affixed to the front panel during assembly provides the exact identification of the boiler and indicates its...

Page 9: ...A 6 Main dimensions Connection for safety valves Rp 1 Heating outlet R 1 1 2 Heating return R 1 1 2 Draining Rp 3 4 Gas inlet R 1 Boiler Gas 360 S 8 10 12 14 A mm 946 1113 1280 1447 B mm 952 1007 1007...

Page 10: ...e valve VP2 opens Behaviour in abnormal conditions If the flame is not detected before the end of the safety time ts the safety control box goes into safety lockout and the safety lockout warning ligh...

Page 11: ...sformer TCH1 Boiler thermostat 1 Speed TCH2 Boiler thermostat 2 Speed VA Safety lockout warning light VBa Ignition burner valve VP1 Main burner valve 1 Speed VP2 Main burner valve 2 Speed t3n Flame st...

Page 12: ...ntrol valve 2 Safety solenoid valve 3 Gas inlet 4 Safety valve quality level B 5 Gas filter 6 Valve 7 Pressure adjustment screw 8 Pressure socket 9 Membrane 10 Main valve quality level D 11 Outlet to...

Page 13: ...socket 3 Output pressure socket 4 Safety solenoid valve 5 Lower regulation chamber 6 Controlled regulation flap 7 Distribution channel 8 Solenoid control valve 9 Threshold ignition system 10 Lower mem...

Page 14: ...m spanner and fit the new nozzles with their new seals First tighten the nozzles by hand and carefully lock them using a spanner Carry out a leak tightness check 2 Changing the ignition burner injecto...

Page 15: ...essure outlet on the manifold Turn the boiler on Set the boiler thermostats to maximum Unscrew the protection cap on each valve Set the pressure on the left and right valves as shown in the table in t...

Page 16: ...rewdriver In the factory it is set to maximum To modify this setting it necessary first to remove the protection using a screwdriver 1 4 turn The progressivity of the left valve 2nd stage is always se...

Page 17: ...677 17 Remeha Gas 360 S 20 07 05 300005180 001 A 4 1 Operation of the progressivity screw setting A Downstream pressure mbar B Time s 5 Attaching the label Affix the label which indicates for which ty...

Page 18: ...bar Boiler type Gas 360 S 8 10 12 14 Nozzle pressure Natural gas H mbar 14 14 14 14 Propane mbar 36 36 36 36 Start up pressure Natural gas H mbar 11 11 11 11 Propane mbar 10 10 10 10 Nozzle Number of...

Page 19: ...e socket located on the manifold Check that the nozzle pressure and the start up pressure match the pressures given in the relevant chapter Pressure settings and calibrated nozzle markings If necessar...

Page 20: ...dy must be checked once a year If it is necessary to sweep the boiler remove the burner drawer to prevent deposits and soot blocking the orifices in the gas trains With the burner out Take the column...

Page 21: ...lectrode gap 9 and the position of the flame diffuser 17 in terms of the sizes indicated on the drawing required in the event of heater malfunction After reassembly check for leak tightness 1 3 Painte...

Page 22: ...into standby burner cut and the alarm indicator flashes Anti blowback thermostat cut Check for adequate draw on the chimney connection Press the reset button on the safety control box Check that the d...

Page 23: ...Heater too hot or too cold for requirements 3 position switch on position Check the position of the 3 position switch Wrong setting for the heater thermostat Set the heater thermostat if the heater ha...

Page 24: ...heating spares co Tel 0161 620 6677 Spare parts Gas 360 S The code number on the list next to the required piece must be stated when ordering replacement parts 20 07 05 300005180 002 A Boiler body Dr...

Page 25: ...Supplied By www heating spares co Tel 0161 620 6677 25 Remeha Gas 360 S 20 07 05 300005180 001 A Gas line 8 10 12 sections...

Page 26: ...Supplied By www heating spares co Tel 0161 620 6677 26 Remeha Gas 360 S 20 07 05 300005180 001 A Gas line 14 sections...

Page 27: ...Supplied By www heating spares co Tel 0161 620 6677 27 20 07 05 300005180 001 A Remeha Gas 360 S Control panel K Control panel K Components...

Page 28: ...Supplied By www heating spares co Tel 0161 620 6677 28 Remeha Gas 360 S 20 07 05 300005180 001 A Metal casing for control panel K...

Page 29: ...Supplied By www heating spares co Tel 0161 620 6677 29 20 07 05 300005180 001 A Remeha Gas 360 S Boiler body insulation...

Page 30: ...Supplied By www heating spares co Tel 0161 620 6677 30 Remeha Gas 360 S 20 07 05 300005180 001 A Cladding...

Page 31: ...pipe 12 sections 17 9754 9672 Return pipe 14 sections 18 9755 0189 Flange gasket 19 8377 4091 Insulation outlet pipe 20 9696 0228 Brush 22 x 11 L500 21 8800 8966 Box of mastic 1 kg 22 9430 5027 Putty...

Page 32: ...8502 8108 Flame non return plate 8 sections 74 8377 8188 Flame non return plate 10 sections 74 8377 8190 Flame non return plate 12 sections 74 8377 8192 Flame non return plate 14 sections 75 8800 8961...

Page 33: ...177 200003526 Complete upper front panel 8 sections 177 200003527 Complete upper front panel 10 sections 177 200003528 Complete upper front panel 12 sections 177 200003529 Complete upper front panel 1...

Page 34: ...Supplied By www heating spares co Tel 0161 620 6677 Remeha Gas 360 S 20 07 05 300005180 001 A...

Page 35: ...Supplied By www heating spares co Tel 0161 620 6677 Remeha Gas 360 S 20 07 05 300005180 001 A...

Page 36: ...ra 55 59 08005 BARCELONA Tel 34 3 3000204 Fax 34 3 3009558 E Cuatrocesa S A c Sor Angela de La Cruz 10 1 Oficina C 28020 MADRID Tel 34 91 658 18 88 Fax 34 91 658 30 77 E D A C S A Tom s A Edison 29 Po...

Reviews: