Non-observance of the recommended form of MT strip edges can result in 

stitching discrepancies and MT jamming in the MOV USB device. Use of polluted 

and damaged MT leads to device malfunction.

To  renew  ethyl  alcohol  operating  reserve,  take  the  container  for  alcohol  from  the  box 

(Figure 7d), remove the cap, unscrew the head and pour about 5 ml of ethyl alcohol. Screw 

the head of the container and put the cap back on its place.

2.2.2.3 MCAS intended use

The MCAS can be used after the requirements of paragraph 2.2.1 are fulfilled and the steps 

described in paragraph 2.2.2.2 are completed.

Magnetic copying of an object using MCAS consists of the following steps:

 

z

preparing the examined surface,

 

z

selecting MT type,

 

z

preparing (demagnetizing) MT,

 

z

magnetic copying.

Selecting the MT type

The User is to select the MT type (metal or plastic) and width (1’’ or ½’’). The following 

recommendations should be taken into consideration.

 

z

Plastic MT is considerably less expensive than metal MT. As technical properties of both 

MT types are almost the same, plastic MT can be used in the majority of cases.

 

z

It is recommended NOT TO USE plastic MT in the conditions which worsen the quality 

of  magnetic  copying  and  shorten  MT  lifetime,  e.g.  on  very  rough  surfaces  (severe 

corrosion, premilling), on hot surfaces (when surface temperature e50 ˚C), on 

surfaces with sticky stains that cannot be removed.

 

z

It is recommended TO USE plastic MT in the conditions which improve the quality of 

magnetic copying, e.g. for examining the relief and structure of aluminum objects, for 

examining  weak  internal  stresses  in  ferromagnetic  objects,  for  magnetic  copying  in 

narrow openings and in grooves where the only way to avoid MT damage is to use ½’’ 

plastic MT.

Preparing the examined surface

 

z

Provide easy access to the examined surface: take off jackets, side plates, detachable 

equipment.

 

z

Clean the examined surface from foreign particles (such as dust, dirt, sand, tar, etc.), as 

well as from lubricant films. If necessary, clean it with ethyl alcohol, then dry or remove 

moisture.  Dirty  MT  slightly  worsens  the  quality  of  magnetic  copying,  but  it  leads  to 

untimely magnetic tape wear. The particles adhered to the tape damage the magneto-

optical crystal and foul the tape-drive mechanism.

ATTENTION! DO NOT REMOVE RUST FROM THE SURFACE!

Rust layer, especially on the heavily corroded surfaces, often is the only remaining 

carrier of information about original numbers.

Preparing (Demagnetizing) MT

 

z

Take the CMS out of the MCAS compartment.

 

z

Select a used (after visualization) MT strip.

 

z

Press  and  hold  the  demagnetizer  drive  button  (Figure  8,  pos.  1).  Insert  the  end  of 

the MT strip (Figure 8, pos. 6) into the demagnetizer slot and slightly push it forward 

until its end appears on the opposite side.

 

z

Release  the  demagnetizer  drive  button  (Figure  8,  pos.  1),  take  the  threaded  end  of 

the MT strip and pull it through the demagnetizer.

 

z

Use the demagnetized MT for carrying out a new magnetic copy or place it into the cartridge 

for demagnetized MT (marked with green marker) (Figure 6a, b).

Summary of Contents for 7517A

Page 1: ...WARE AND SOFTWARE SYSTEM FOR FORENSIC EXAMINATION OF FIREARMS AND AMMUNITION SERIAL NUMBERS REGULA 7517 MAGNETO OPTICAL DEVICE REGULA 7517A USER S GUIDE Certified Quality Management System Regula Ltd...

Page 2: ......

Page 3: ...sories Set MCAS 13 1 2 3 Personal Computer PC 14 1 2 4 Software 15 1 2 5 Spare Parts and Repair Kit SPRK 15 2 INTENDED USE 16 2 1 Device Intended Use 16 2 1 1 Safety measures and operating limitations...

Page 4: ...ssories set MOI magneto optical image MOV magneto optical visualization MOV USB device USB device for magneto optical visualization OMB optic mechanical block MT magnetic tape SPRK spare parts and rep...

Page 5: ...ining and get clearance to perform expert examination in the field of trace evidence z z be an OS Windows user z z study techniques of authenticity verification of firearms and ammunition serial numbe...

Page 6: ...laboratory conditions due to the fact that the device provides high quality results visual evidence and uses non destructive magneto optical methods In case any changes in serial numbers are detected...

Page 7: ...than 5 years Operation warranty period 12 months from the date the device is delivered to the customer Storage warranty period 12 months Dimensions In transportation packaging not more than 350 280 22...

Page 8: ...sories 1 box 1b Peripheral examination tools Regula 7516 body case Regula 7516 Software PC drivers and utilities CD folder CD 1 OS Windows XP CD 2 MS Office CD 3 Special software for managing USB devi...

Page 9: ...where it is automatically detected and introduced into the tape drive tract Then it is scanned step by step by a sensor designed on the basis of a magneto optical crystal Magneto optical visualizatio...

Page 10: ...g with fusible metals dot welding and pressing in fragments See paragraph 2 2 1 2 for the details of the device operational check up using the test object Test object specifications The test object se...

Page 11: ...r s name and or trade mark z z manufacturer s model identification z z device serial number in compliance with the numbering system of the manufacturer z z date of manufacturing year and month z z rat...

Page 12: ...te time of input of a magnetic copy of the number platform 15 sec OS WindowsXPorlater Format of image files BMP PCX GIF JPG PC monitor size 12 Approximate size of an image file of the number platform...

Page 13: ...he copy reflects relief and structural inhomogeneity of the material Permanent magnets of the combination magnetic scanner CMS concentrators serve as sources of magnetic stray fields excitation z z De...

Page 14: ...ced examination of metal structure of objects is the eddy current scanner supplied optionally Its specifications are given in the user s guide to eddy current magnetographing device Regula 7517B Magne...

Page 15: ...ion results Detailed description of NUCA EYER software is given in the corresponding user s guide Spare Parts and Repair Kit SPRK Function SPRK is intended for routine maintenance and repairs of the d...

Page 16: ...z Consider operating limitations for the components of the device in conformity with paragraph 2 2 2 2 1 2 1 1 Failure to observe operating limitations given in paragraphs 2 1 1 and restrictions on th...

Page 17: ...rnal power supply source The device can be powered by the internal autonomous PC battery In this case power supply cables are not connected z z Switch on the PC Start the OS and launch NUCA EYER softw...

Page 18: ...d it will move forward automatically z z Wait for approximately 5 seconds to load the potentially informative sector of the magnetic copy into MOV zone Start the stitching process by corresponding sof...

Page 19: ...mined number Measure geometric dimensions of the images of the digits and analyze their position The software allows measuring linear and angular image dimensions z z Analyze examination results Docum...

Page 20: ...Figure 5a to move the MT strip Figure 5 pos 3 through the slot beyond the edge of the blade Figure 5 pos 2 z z Take the MT by its edge Figure 5 pos 3 and pull it out for a required length relative to...

Page 21: ...netized MT Inserting MT strips into the cartridge and extracting them Figure 6 d c b 1 cartridge for storing MT 2 magnetic clamp 3 MT 1 2 To insert MT strips into the cartridge do the following Roll u...

Page 22: ...irty MT surface greasy film water solvents chemical solutions particles of dust rust metal etc MT surface should be cleaned with alcohol using a special container from the SPRK Figure 7d MT with consi...

Page 23: ...tic MT in the conditions which improve the quality of magnetic copying e g for examining the relief and structure of aluminum objects for examining weak internal stresses in ferromagnetic objects for...

Page 24: ...h a magnetic clamp Figure 9 pos 2 z z Put the MT strip upon the prepared number platform and fix the MT end on the examined surface using a magnetic clamp avoid warps and shifts relative to the examin...

Page 25: ...spring clip z z Select the CMS concentrator according to the properties of the examined object z z Make a magnetic copy Lower the concentrator of the magnetic scanner unto the fixed MT strip and slig...

Page 26: ...ed object may appear z z Put the magnetic copy into the corresponding cartridge for storing MT see Figures 6a b The one for storing MT with recorded data is marked with red marker If necessary use the...

Page 27: ...ing the cleaning tape wait for at least 3 minutes until the tape drive surfaces get dry before starting device operation Rate of one time ethyl alcohol application 0 5 g Maintenance of the MOV USB dev...

Page 28: ...surface measure the thickness of lacquer and paint coating When examining the stitched image there are image fragments irrelevant to the examined object MT is not completely demagnetized Demagnetize t...

Page 29: ...the button of the pressing roller block It is strictly prohibited to use metal instruments for extracting foreign objects from the tract If the described methods are ineffective it is recommended to a...

Page 30: ...screw for about 1 mm Then put pieces of cardboard on the arrises and tighten plastic straps Figure 12 pos 2 The device is to be stored in climatic conditions given in paragraph 5 Protect the device fr...

Page 31: ...ULA Ltd Address for mailing claims with regard to the quality of the device 1 Volokha Street Office 314 Minsk 220036 Republic of Belarus Phone 375 17 2862825 Fax 375 17 2136897 e mail support regulafo...

Page 32: ...1 Volokha Street Office 314 Minsk 220036 Republic of Belarus Phone 375 17 2862825 Fax 375 17 2136897 e mail mail regula by http www regulaforensics com...

Reviews: