The CMS flat concentrator 

is designed for copying relief surfaces with unevenness not 

exceeding 0,5 mm at the base width of 11 mm The CMS flat concentrator has the strongest 

magnetic flow compared to the other scanners. Thus, it is mainly used for examining structural 

inhomogeneity of metal surfaces.

Rotary concentrators of the CMS 

are  designed  as  the  system  of  floating  disks  for 

magnetic copying of more complex relief surfaces with unevenness not exceeding 1 mm at 

the base width of 20 mm. The CMS rotary concentrators form surface magnetic flow. Therefore 

they  are  mainly  used  for  examination  of  relief  inhomogeneity  of  metal  surfaces  (front  side 

of the number platform, defective welded seams). They have the highest penetrating ability 

through  lacquer-and-paint  coating.  Stronger  magnetization  is  provided  by  the  concentrator 

with a smaller effective width. That is why the use of 15 mm concentrator is more preferable 

for detailed examination. The use of 21 mm concentrator is more preferable for increasing 

the examined area.

The compact magnetic scanner 

is  equipped  with  a  flat  concentrator  on  permanent 

magnets with  effective  width  of 11  mm. Due to  the  minimal  size  the  scanner can be  used 

on difficult surfaces: grooves, joints or abutment of examined object elements. Magnetizing 

properties  of  this  scanner  occupy  an  intermediate  position  among  the  CMS  concentrators. 

The compact magnetic scanner is equipped with a spring clip which can be fixed in one of two 

positions. The operator can choose a suitable position relative to the direction of scanning.

The  most  effective  device  for  advanced  examination  of  metal  structure  of  objects  is 

the eddy-current scanner

  (supplied  optionally).  Its  specifications  are  given  in  the  user’s 

guide to eddy-current magnetographing device Regula 7517B.

Magnetic tape cartridges 

are used for storing operating reserve of MT. The cartridges are 

marked: 1) the cartridge for MT that has recorded information is marked with a red marker, 

2) the cartridge for demagnetized MT is marked with a green marker. Cartridges can be either 

attached to magnetic clamps (Figure 6) or kept separately. 

Magnetic clamps 

are used to fix a MT strip on the examined area during magnetic copying.

Use a container with operating reserve of alcohol and a brush when preparing the object 

surface for magnetic copying. Use a marker for marking magnetic copies.

Some accessories for magnetic copying and 

SPRK

 are kept in the accessories bag: 

 

z

CMS rotary concentrator (21 mm),

 

z

compact magnetic scanner (11 mm) (Figure 10, pos. 1),

 

z

container for alcohol (10 g),

 

z

marker,

 

z

brush,

 

z

MT cutter with technological reserve of MT — 10 m roll (Figure 5),

 

z

test-object (Figure 2),

 

z

CMS sleeve gaskets.

Personal Computer (PC)

Function

The PC with special software manages various USB-devices of Regula 7517A (MOV, optical 

input),  displays  operative  and  stored  information,  provides  conditions  for  its  processing, 

examination and documenting.

Technical specifications

The device can operate with a desktop PC or with a laptop.

For  NUCA  (EYER)  software  operation  the  following  PC  specifications  are  required:

 

z

IBM-compatible PC,

 

z

CPU — Celeron 2 GHz, Intel Pentium IV or higher,

 

z

OS — Windows XP (SP2 or higher), Windows 2000 (SP2 or higher),

 

z

available USB 2.0 port with high speed support,

 

z

RAM — 512 Mb or higher,

 

z

video adapter supporting 1280x1024, 24-bit color mode,

 

z

MS DirectX v.9.0b or higher.

1.2.3

Summary of Contents for 7517A

Page 1: ...WARE AND SOFTWARE SYSTEM FOR FORENSIC EXAMINATION OF FIREARMS AND AMMUNITION SERIAL NUMBERS REGULA 7517 MAGNETO OPTICAL DEVICE REGULA 7517A USER S GUIDE Certified Quality Management System Regula Ltd...

Page 2: ......

Page 3: ...sories Set MCAS 13 1 2 3 Personal Computer PC 14 1 2 4 Software 15 1 2 5 Spare Parts and Repair Kit SPRK 15 2 INTENDED USE 16 2 1 Device Intended Use 16 2 1 1 Safety measures and operating limitations...

Page 4: ...ssories set MOI magneto optical image MOV magneto optical visualization MOV USB device USB device for magneto optical visualization OMB optic mechanical block MT magnetic tape SPRK spare parts and rep...

Page 5: ...ining and get clearance to perform expert examination in the field of trace evidence z z be an OS Windows user z z study techniques of authenticity verification of firearms and ammunition serial numbe...

Page 6: ...laboratory conditions due to the fact that the device provides high quality results visual evidence and uses non destructive magneto optical methods In case any changes in serial numbers are detected...

Page 7: ...than 5 years Operation warranty period 12 months from the date the device is delivered to the customer Storage warranty period 12 months Dimensions In transportation packaging not more than 350 280 22...

Page 8: ...sories 1 box 1b Peripheral examination tools Regula 7516 body case Regula 7516 Software PC drivers and utilities CD folder CD 1 OS Windows XP CD 2 MS Office CD 3 Special software for managing USB devi...

Page 9: ...where it is automatically detected and introduced into the tape drive tract Then it is scanned step by step by a sensor designed on the basis of a magneto optical crystal Magneto optical visualizatio...

Page 10: ...g with fusible metals dot welding and pressing in fragments See paragraph 2 2 1 2 for the details of the device operational check up using the test object Test object specifications The test object se...

Page 11: ...r s name and or trade mark z z manufacturer s model identification z z device serial number in compliance with the numbering system of the manufacturer z z date of manufacturing year and month z z rat...

Page 12: ...te time of input of a magnetic copy of the number platform 15 sec OS WindowsXPorlater Format of image files BMP PCX GIF JPG PC monitor size 12 Approximate size of an image file of the number platform...

Page 13: ...he copy reflects relief and structural inhomogeneity of the material Permanent magnets of the combination magnetic scanner CMS concentrators serve as sources of magnetic stray fields excitation z z De...

Page 14: ...ced examination of metal structure of objects is the eddy current scanner supplied optionally Its specifications are given in the user s guide to eddy current magnetographing device Regula 7517B Magne...

Page 15: ...ion results Detailed description of NUCA EYER software is given in the corresponding user s guide Spare Parts and Repair Kit SPRK Function SPRK is intended for routine maintenance and repairs of the d...

Page 16: ...z Consider operating limitations for the components of the device in conformity with paragraph 2 2 2 2 1 2 1 1 Failure to observe operating limitations given in paragraphs 2 1 1 and restrictions on th...

Page 17: ...rnal power supply source The device can be powered by the internal autonomous PC battery In this case power supply cables are not connected z z Switch on the PC Start the OS and launch NUCA EYER softw...

Page 18: ...d it will move forward automatically z z Wait for approximately 5 seconds to load the potentially informative sector of the magnetic copy into MOV zone Start the stitching process by corresponding sof...

Page 19: ...mined number Measure geometric dimensions of the images of the digits and analyze their position The software allows measuring linear and angular image dimensions z z Analyze examination results Docum...

Page 20: ...Figure 5a to move the MT strip Figure 5 pos 3 through the slot beyond the edge of the blade Figure 5 pos 2 z z Take the MT by its edge Figure 5 pos 3 and pull it out for a required length relative to...

Page 21: ...netized MT Inserting MT strips into the cartridge and extracting them Figure 6 d c b 1 cartridge for storing MT 2 magnetic clamp 3 MT 1 2 To insert MT strips into the cartridge do the following Roll u...

Page 22: ...irty MT surface greasy film water solvents chemical solutions particles of dust rust metal etc MT surface should be cleaned with alcohol using a special container from the SPRK Figure 7d MT with consi...

Page 23: ...tic MT in the conditions which improve the quality of magnetic copying e g for examining the relief and structure of aluminum objects for examining weak internal stresses in ferromagnetic objects for...

Page 24: ...h a magnetic clamp Figure 9 pos 2 z z Put the MT strip upon the prepared number platform and fix the MT end on the examined surface using a magnetic clamp avoid warps and shifts relative to the examin...

Page 25: ...spring clip z z Select the CMS concentrator according to the properties of the examined object z z Make a magnetic copy Lower the concentrator of the magnetic scanner unto the fixed MT strip and slig...

Page 26: ...ed object may appear z z Put the magnetic copy into the corresponding cartridge for storing MT see Figures 6a b The one for storing MT with recorded data is marked with red marker If necessary use the...

Page 27: ...ing the cleaning tape wait for at least 3 minutes until the tape drive surfaces get dry before starting device operation Rate of one time ethyl alcohol application 0 5 g Maintenance of the MOV USB dev...

Page 28: ...surface measure the thickness of lacquer and paint coating When examining the stitched image there are image fragments irrelevant to the examined object MT is not completely demagnetized Demagnetize t...

Page 29: ...the button of the pressing roller block It is strictly prohibited to use metal instruments for extracting foreign objects from the tract If the described methods are ineffective it is recommended to a...

Page 30: ...screw for about 1 mm Then put pieces of cardboard on the arrises and tighten plastic straps Figure 12 pos 2 The device is to be stored in climatic conditions given in paragraph 5 Protect the device fr...

Page 31: ...ULA Ltd Address for mailing claims with regard to the quality of the device 1 Volokha Street Office 314 Minsk 220036 Republic of Belarus Phone 375 17 2862825 Fax 375 17 2136897 e mail support regulafo...

Page 32: ...1 Volokha Street Office 314 Minsk 220036 Republic of Belarus Phone 375 17 2862825 Fax 375 17 2136897 e mail mail regula by http www regulaforensics com...

Reviews: