Regency HZ33CE Gas Fireplace
5
SAFETY LABEL
This is a copy of the label that accompanies each HZ33CE Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.
NOTE:
Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
COPY OF SAFETY DECAL
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas fi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible con-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
406
406
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
NATURAL GAS:
Model HZ33CE-NG
PROPANE:
Model
-LP
HZ33CE
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
DOOR SEAL: Please check that
the door is properly sealed
FPI Fireplace Products International Ltd.
Delta, BC, Canada
Minimum Clearances to Combustibles
Degagement Minimum De Materiaux Combustibles
0" Clearance to
combustibles from:
Ceiling Clearances from
Top Opening of Unit:
Side Wall Clearance from
Side Opening of Unit:
Sides, bottom and rear of unit
*Top - 3-1/2" (89mm) non-combustible
material required above unit.
(A) 30" (762mm)
B) 9"(229mm)
Floor Clearance:
Alcove Clearances
C) 0”
D)
E)
Min. Width 84" (1219mm)
Max. Depth 36" (914mm)
(
See Instruction Manual for Detailed Instructions)
Serial No./ No de serie
919-119
5"
WC
(1.25 kPa)
3.5"
WC
(0.87 kPa)
1.6"
WC
(0.39 kPa)
# 47
DMS
0-4500 ft/pi
(0-1372 m)
12,000 Btu/h (3.51 kW)
17,000 Btu/h (4.98 kW)
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
Pression a la tubulure d' chappement lev e
Pression a la tubulure d' chappement basse
Grandeur de l'injecteur
D bit Califorique minimum selon
D bit Caliorfique maximum selon
l'altitude
Modéle
-NG
HZ33CE
é
é
é
é
é
é
APPAREIL FONCTIONNANT AU PROPANE
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
Pression a la tubulure d' chappement lev e
Pression a la tubulure d' chappement basse
Grandeur de l'injecteur
D bit Califorique minimum selon
D bit Caliorfique maximum selon
l'altitude
Modéle
-LP
HZ33CE
é
é
é
é
é
é
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
Listed:
Certified for/Certifi e pour:
Tested to:
VENTED GAS FIREPLACE HEATER
CANADA and U.S.A.
é
CAN/CGA-2.17-M91(R2009)
ANSI Z21.88-2009/CSA 2.33-2009
Model/Modele:
-NG
HZ33CE
Model/Modele:
-LP
HZ33CE
Made in Canada / Fabrique au Canada
Duplicate S/N
11"
WC
(2.73 kPa)
10"
WC
(2.49 kPa)
6.4"
WC
(1.59 kPa)
# 56
DMS
0-4500 ft/pi
(0-1372 m)
12,500 Btu/h (3.66 kW)
15,000 Btu/h (4.39 kW)
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard.
Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
For use with glass doors certified with the appliance only
This vented gas fireplace heater is not for use with air filters.
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Fan (Part # 432-917)
Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les
règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil
VENTED GAS FIREPLACE HEATER -
NOT FOR USE WITH SOLID FUELS.
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
FOYER AU GAZ À ÉVACUATION -
4001172
A
Floor
Wall
Ceiling
C