This is a copy of the label that accompanies each Bellavista™ B36XTE Direct Vent Gas Fireplace. We
have printed a copy of the contents here for your review.
NOTE:
Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference,
the label on the unit is the correct one.
COPY OF SAFETY DECAL
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas fitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli
-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
377
377
DOOR SEAL: Please
check that the door is
properly sealed
FPI Fireplace Products International Ltd. Delta, BC, Canada
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
Serial No./ No de serie
919-391a
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
Electrical supply/Électrique 115VAC, 1.13 A, 60Hz.
NOT FOR USE WITH SOLID FUELS. /
NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
Made in Canada/ Fabrique au Canada
Duplicate S/N
0" Clearance to
combustibles from:
Top, sides, bottom and rear of unit
Mantel Clearances from
Fireplace Opening:
(A) Min. 13" (330mm)
Side Wall Clearance
from Fireplace Opening
B) Min. 12” (305mm)(on one side)
Ceiling from Top of
Fireplace Opening:
C) 36-3/4” (933mm)
Mantel Depth:
D) Max. 12” (304mm)
Alcove Clearances:
E) Min. Width 84" (2134mm),
F) Max. Depth 36" (914mm)
Minimum Vent Clearances:
Horizontal Top 2" (51mm)
Horizontal Side 1-1/2" (38mm)
Horizontal Bottom 1-1/2" (38mm)
Vertical Vent 1-1/2" (38mm)
(
See Instruction Manual for
detailed instructions)
É
É
QUIP A L'UISINE POUR GAZ PROPANE
CONCU POUR ETRE POELE: Mod le B36XTE-LP10
é
PROPANE GAS: Model B36XTE-LP10
NATURAL GAS: Model B36XTE-NG10
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mod le B36XTE-NG10
é
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
é
é é
Pression à la tubulure d' chappement basse
é
Grandeur de l'injecteur
D bit Calorifique minimum selon
é
D bit Calorifique maximum selon
é
l'altitude
5.0" WC/C.E. (1.25 kPa)
3.5" WC/C.E. (0.87 kPa)
1.6" WC/C.E. (0.40 kPa)
# 35 DMS
21,500 Btu/h (6.3 kW)
31,000 Btu/h (9.09 kW)
0-4500 ft/pi (0-1372 m)
Part #: 919-391
Colour: Everything black on grey except what is highlighted is printed red.
Size: File@100%
June 17/14 : Created Draft
May 11/15:
Rev. A - added screen part # with Louvers
*
Printer
: Continue number sequence from 918-953 - do not restart at 0
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
é
é é
Pression à la tubulure d' chappement basse
é
Grandeur de l'injecteur
D bit Calorifique minimum selon
é
D bit Calorifique maximum selon
é
l'altitude
11" WC/C.E. (2.74 kPa)
10" WC/C.E. (2..49 kPa)
6.4" WC/C.E. (1.60 kPa)
# 51 DMS
25,000 Btu/h (7.33 kW)
31,000 Btu/h (9.09 kW)
0-4500 ft/pi (0-1372 m)
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in
the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. (Kit #576-972).
Fan Part # 576-917.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety
Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si
les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC L'APPAREIL
For Use Only with Barrier (Part #578-005 with Vignette) or (Part #578-929 Installed with Flush Panels) Follow installation instructions.
Utiliser uniquement avec l’écran ( n ° 578-005 avec Vignette) ou ( n ° 578-929 Installation avec Panneaux Plats) Suivre les instructions d'installation.
E
B
A
C
D
F
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in
the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. (Kit #556-969).
Certified for use with Heat Wave (Kit #946-556). Fan Part # 910-215/P.
«Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.»
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety
Standard. Si ces normes ne sont pas pertinentes, utilisez la norme.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si
les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC L'APPAREIL
4001172
Listed:
VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour:
CANADA and U.S.A.
é
Tested to:
CAN/CGA-2.17-M91(R2009)
ANSI Z21.88-2014
Conforms to:
CSA 2.33-2014
Certified to: