12
|
Bellavista® B36XTE-10 Gas Fireplace
|
12
installation
Note:
Ensure the paint that is used on the mantel and the facing is "High Quality" or the paint may discolour.
Mantel Clearances
B36XTE
A
B
C
D
From Top of Fireplace
Opening
32"
(813mm)
22"
(559mm)
17-1/2""
(445mm)
13"
(330mm)
COMBUSTIBLE MANTEL CLEARANCES
Because of the extreme heat this fireplace emits, the mantel clearances are critical.
Combustible mantel clearances from top of unit are shown in the diagram below.
Note: Mantel starts at *1" deep and ends at *12" deep.
**For Vignette with Vignette Finishing Trim flush finish
, all materials (framing & finishing) below
the mantel and the width of the Vignette finishing trim,
(37-3/4")
must be non-combustible if a lower mantel is desired.
Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.
Mantel Clearance with Vignette (No Vignette Trim) and
Flush Panels and Safety Screen
Mantel Clearance with Vignette and Vignette
Finishing Trim