58
|
Bellavista® B36XTE-10 Gas Fireplace
|
58
installation
918-821b
06/16/15
4
LINE VOLTAGE WIRING TO RECEPTACLE IN UNIT
TO MAKE OUTLETS INDEPENDENT OF EACH OTHER
ELECTRICAL WORK MUST BE
PERFORMED BY A QUALIFIED
ELECTRICIAN
*
Using Wall Switch only to turn lights ON/OFF.
Scheme - 1
Optional Lights
120 V (60 HZ) power
into receptacle
Receptacle dedicated use by
* AC adaptor
Break Tab on
Black (hot) side
Ground
Ground (Copper)
Black (Hot)
White (Neutral)
Do not break Tab on
White (neutral) side
Clamp Connector
Receptacle located inside the unit
* - Supplied with the appliance
NOTE: ON/OFF switch, all wires supplied by others.
Scheme- 2
Only Use if Optional Fan is purchased.
Green
Optional Accent Light
Receptacle located inside the unit
Extension Cord
NOTE: Lights can be turned ON and OFF using
the remote control AUX function on the hand held transmitter.
See Remote Control instructions for details. No switch is required.