22
|
Bellavista® B36XTE-10 Gas Fireplace
|
22
installation
VENT RESTRICTOR, BAFFLE & HEAT DEFLECTOR INSTALLATION
NOTE: THE VENT RESTRICTOR & BAFFLE MUST BE INSTALLED PRIOR TO OPTIONAL PANEL INSTALLATION.
Note: If installing brick/optional panels, see brick/optional panel
instructions before proceeding to next step.
Diagram 2 Vent restrictor installed on top exhaust assembly
6)
From
inside
the firebox, install the baffle plate with 4 - 1/4" x 1/2 "
screws. Ensure all screws are tight, but do not over tighten.
Baffle Plate
Diagram 3
7)
From
inside
the firebox, install the top heat deflector with 2 -
1/4" x 1/2" screws. Ensure all screws are tight, but do not over
tighten.
Heat Deflector
Diagram 4
1)
Determine the venting configuration.
2)
Remove top heat deflector and baffle plate (reverse of steps 5 & 6).
3)
Go to venting arrangements section (in the manual) to determine if
a vent restrictor setting is required.
Note:
The vent restrictor does not apply to rear vent applications.
4)
Align the vent restrictor plate to the required vent restrictor position
as per the Diagrams shown.
5)
Once the vent restrictor plate is in the required position, secure with
2 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over
tighten. (See Diagram 2).
VENTING
INTRODUCTION
The B36XTE uses the "balanced flue" technology Co-Axial system. The
inner liner vents products of combustion to the outside while the outer liner
draws outside combustion air into the combustion chamber thereby eliminating
the need to use heated room air for combustion and losing warm room air up
the chimney.
Note: These flue pipes must not be connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of
the building, and never be attached to a chimney serving a separate solid fuel
or gas burning appliance. Each direct vent gas appliance must use it's own
separate vent system. Common vent systems are prohibited.