VALVE ASSEMBLY REPLACEMENT
1. Turn off gas supply
2. Remove the pilot shield.
3. Remove glass crystals and log set, if installed.
4. Locate and remove 22 screws to remove the burner tray.
8. Turn off gas supply and remove flex connection at valve.
9. Remove orange EV1 wire and ground wire connected to the gas valve.
10. Remove green EV2 wire connected to the gas valve.
11.
Remove 10 screws securing valve assembly.
12.
Lift valve assembly up and out.
13. Remove both yellow/green ground wires from valve and valve bracket.
14. Replace valve assembly gasket if necessary.
15. Rotate HI/LO modulating valve all the way to the left for HI position.
16. Install new valve assembly and reverse steps 11-1.
17. Test gas connections for leaks.
Turn the unit off and allow to cool to room temperature.
5. Lift burner tray off.
6. Remove 2 screws and slide burner tube to the left (away from the orifice)
to remove.
7. Remove 8 screws on valve access cover.
Ground wire
location (Ground
wire not shown) EV1
EV2