![Regency Fireplace Products Plateau PTO50 Owners & Installation Manual Download Page 12](http://html1.mh-extra.com/html/regency-fireplace-products/plateau-pto50/plateau-pto50_owners-and-installation-manual_1433974012.webp)
12
|
Regency Plateau® PTO50 Outdoor Gas Fireplace
|
12
installation
INNER FRAMING DIMENSIONS (REQUIRED)
NOTE:FRAMING MATERIAL NOT SUPPLIED
56-3/4" (1441mm)
TOP VIEW
SIDE VIEW
END VIEW
8-1/2" (216mm)
8-1/2" (216mm)
11-3/8" (289mm)
56-3/4" (1441mm)
NOTE:
Framing materials must be non-combusti-
ble when used within 5" of the unit.
Combustible framing materials may be
used outside the 5" clearance range.
Note:
The PTO30 non combustible clearance
is 4", although when combining it with a
PTO50 to make a PTO80 the clearance
will be 5".
Finishing materials
MUST
be non-combustible.
Consideration should be given to weather /
elements when choosing framing materials (ie.
treated lumber, steel stud).
PTO80
PTO50
NOTE:
PTO50 - Two (2) ventilation grills are required for all enclosures.
This is to alleviate moisture and allow for air to circulate. Minimum recommended size 20" sq (508 mm²)
ea
.
The ventilation grills must be located at the ends of the burner as shown.
NOTE:
PTO80 - Four (4) ventilation grills are required for all enclosures.
This is to alleviate moisture and allow for air to circulate. Minimum recommended size 20" sq (508 mm²)
ea
.
The ventilation grills must be located at the ends of the burner as shown.
Vent Grill
Location
Vent Grill
Location
Vent Grill
Location
Vent Grill
Location
END VIEW
8-1/2" (216mm)
11-3/8" (289mm)
90" (2286mm)
8-1/2" (216mm)
90" (2286mm)
TOP VIEW
SIDE VIEW
Vent Grill Location
Vent Grill
Location
Vent Grill
Location
Vent Grill
Location
Vent Grill Location
Vent Grill
Location