56 | Gi29 Direct Vent Gas Insert
installation
WiringDiagrams
This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch, optional remote control, and thermostat will
continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.
CA
UTION
Ensurethatthewiresdonottouchanyhotsurfacesand
areawayfromsharpedges.
ITEM PART #
DESCRIPTION
1
904-153
Star Lock Washer
2
904-330
8-32 Hex Nut
3
904-612
8-32 x 1/2" Ground Lug
4
904-169
#10 Split Lock Washer
5
910-692
Green Ground Wire
6
N/A
Power Cord Ground Wire
7
910-478
Novasit Gas valve NG/LP
8
910-592-OFT Remote Transmitter
9
911-338/P
Remote Receiver
10
311-526
ON/OFF switch
Assembly
12
910-073
DC Spark Generator Bat
-
tery Box
ITEM PART #
DESCRIPTION
13
910-074
DC Spark Generator
Switch c/w Wires
14
910-038/P
Pilot Assembly - NG
14
910-039/P
Pilot Assembly - LP
15
910-341
Thermopile
16
910-386
Thermocouple
17
910-030
Spark Electrode
18
910-096
3 Way Pilot Hood
19
911-071/P
Blower Motor
20
W241050
Fan Thermodisc
21
910-330
Fan Speed Controller
ITEM PART #
DESCRIPTION
22
904-586
Fan Speed Control Knob
23
911-096
120 Volt Power Cord
24
910-692
Green Ground Wire
25
910-811
Black Wire
26
910-896
Black Wire
27
910-811
ON/OFF Burner Switch
Wire
28
910-818
ON/OFF Burner Switch
Wire
29
910-741
Black Jumper Wire
*Optional remote
N/S
911-164
Remote Wiring Harness
*Optional remote
S.I.T. Valve
S.I.T. Valve
Green/Vert
Neutral/Neutre
Live/
Sous
tension
Black/
Noir
ON
OFF
ON
OFF
Regency
(To/À THTP)
(To/À TH)
Black/
Noir
Black/
Noir
Black/Noir
Black/Noir
Remote
Green/Vert
Black/
Noir
Remote
To/Vers le thermocouple IN
I H
O
L
F
F
O
N
O
O L
I
T
P
White/Blanc
(To/À THTP)
(To/À TH)
DC
SPARKER
Black/Noir
Black/Noir
Red/Rouge
Green/
Vert
Gi29LU
Gi29L
Note:
An optional wall thermostat
could also be wired in place
of the receiver.
Gi29L with optional remote
To/Vers le thermocouple IN
I H
O
L
F
F
O
N
O
O L
I
T
P
White/Blanc
DC
SPARKER
Red/Rouge
Green/
Vert
Green/Vert
Black/Noir
Black/Noir
Black/Noir
White/Blanc
5
6
2
1
4
1
2
3
7
8
9
10
29
13
14
15
18
16
17
21
22
20
26
25
19
24
23
28
27
7
10
13
14
15
18
16
17
28
27
12
12
Thermostat (optional)
Summary of Contents for Gi29L-LP
Page 76: ...76 Gi29 Direct Vent Gas Insert warranty ...
Page 77: ...Gi29 Direct Vent Gas Insert 77 ...
Page 78: ...78 Gi29 Direct Vent Gas Insert ...
Page 79: ......