Gi29 Direct Vent Gas Insert | 55
installation
OptionalRemoteControl
Use the FPI remote control kit supplied with
this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter and a remote receiver.
1. Install three AAA alkaline batteries in the
transmitter and four AA alkaline batteries in
the receiver. Switch the remote receiver to
"remote" mode - it is ready for operation.
1. Clocking the appliance to ensure the correct
firing rate (noted on label) at 15 minutes.
2. If required, adjust the primary air to ensure
that the flame does not carbon. Allow the unit
to burn for 15 min. to stabilize.
3. Check for proper draft.
FinalCheck
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
OptionalWallThermostat
A wall thermostat may be installed if desired. FPI
offers an optional programmable thermostat, but
any 250-750 millivolt rated non-anticipator type
thermostat that is CSA, ULC, or UL approved may
be used.
ThermostatWireTable
CA
UTION
•
Any alteration to the product
thatcausessootingorcarboning
resultingindamagetotheexterior
fasciaisnottheresponsibilityof
themanufacturer.
CA
UTION
•
Donotconnectthemillivoltwall
thermostat wires to the 120V
wires.
Remote receiver
location
NO
TE
• The remote receiver will be located on the
lower right side of the appliance. See below.
RecommendedMaximumLeadLength
(Two-Wire)WhenUsingWall
Thermostat(CP-2System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
18 GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.