64 | Gi29 Direct Vent Gas Insert
maintenance
Door Glass
Your Regency insert is supplied with high
-temperature Neoceram glass that will withstand
the highest heat your unit can produce. If your
glass requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials. Do not clean
the glass when hot.
If you break the door glass, purchase a replacement
from an authorized Regency dealer and follow our
step-by-step instructions for replacement.
General Vent Maintenance
Conduct an inspection of the venting system semi-
annually. Areas to inspect are as follows:
1. Check the venting system for corrosion in areas
exposed to the elements. Components with
rust spots, streaks, or holes should be replaced
immediately.
2. Remove the termination cap and shine a flash
-
light down the vent. Remove any bird nests or
other foreign material.
3. Check for evidence of excessive condensation,
such as water droplets in the inner liner dripping
out the joints. Continuous condensation can
cause corrosion of caps, pipes, and fittings. It
may be caused by excessive lateral runs, too
many elbows, or exposure to cold weather.
4. Inspect joints to verify that no pipe sections or
fittings have been disturbed and consequently
loosened. Also, check mechanical supports such
as wall straps or plumber's tape for rigidity.
LogReplacement
Never use the unit with broken logs. Turn off the
gas valve and allow the unit to cool before carefully
removing the logs. Use the proper replacement log
for any that are broken. Position the logs as shown
in the diagram in the "Log Installation" section of
this manual.
SparkerBatteryChange
1. Pull the sparker box out to access the battery
cover.
2. Compress the clip and remove the sparker bat
-
tery cover.
3. Discard and replace the AA battery.
4. Replace battery cover and press down to close.
NO
TE
• Improper positioning of logs may create
carbon build-up and will alter the unit’s
performance which is not covered under
warranty.
GlassGasket
If the glass gasket requires replacement, use Flush
Front (Part # 936-273). Glass gasket is sold by the
foot; seven feet are required for this installation.
Battery Box
GlassReplacement
In the event that you break your glass,
purchase your replacement from an authorized
Regency® dealer.
Replacement ceramic glass (Part #940-536/P) is
shipped with a gasket.
CA
UTIONS
• Do not clean when the glass is hot.
• T
heuseofsubstituteglasswill
voidallproductwarranties.
•
Takecarenottobreaktheglass.
• Do not
operate this fireplace
withouttheglassfront,orwith
brokenglass.
• Wear
gloves when removing
damagedorbrokenglass.
•
Replacementoftheglasspanel(s)
should be done by a qualified
serviceperson.
ThermodiscReplacement
1. Disconnect the unit from power.
2. Remove the front screen, front glass, log set
and media.
3. Remove fan control box by removing 2 screws.
4. Remove the thermodisc from the clip under
the valve tray by sliding the thermodisc from
left to right and out.
5. Replace the thermodisc with new part.
6. Reverse steps above to re-install.