6
Connect the mains water supply to the Inlet of the shower via 15mm copper, stainless steel or plastic
pipe using a 15mm compression fitting. See (Diagram 4) for advice on Rear Entry fitting.
The Inlet fitting is designed to rotate through 180° to allow for either Top or Bottom/Rear entry fitting
(See Diagrams 3).
Installation Note:
The inlet fitting is designed to enter a compression fitting only. DO NOT use push
Fit connectors as full engagement cannot be guaranteed. DO NOT use excessive force when making
these connections.
Installation Note:
If installing a water feed pipe from the back, the use of a soldered Elbow
Connector is recommended. It should be positioned approximately
87mm
from the
inlet connector
centre. The centre of the inlet connector to the wall surface is
21mm
.
IMPORTANT:
The inlet
fitting MUST be used in the
Bottom fitting position for
Rear fitting. Under NO
circumstances must the
Inlet be rotated 90° and the
pipe fitted directly.
The shower has not been
designed for this method
of connection.
BOTTOM ENTRY
REAR ENTRY
DISCARD
THIS
PART
REFIT THIS
SECTION
DISCARD
THIS
PART
REFIT THIS
SECTION
TOP ENTRY
Diagrams 3