11
Diagram 10
Diagram 11
Diagram 12
Commissioning
Ensure the water and electricity are switched
on to the unit.
Press and hold the
Cooler
button
until
confirmed with
one audible short bleep
.
See Diagram 10
The digital display will illuminate with a capital
“C”
. See Diagram 11
If the button does not respond, ensure that the
flying lead from the PCB has been connected
to the front cover. See Diagram 6
Allow the unit to fill and wait for the water to
come out of the handset then press the
Stop/Start button turning the shower OFF
(Confirm with
three audible short bleeps
).
See Diagram 12
Re-start -
Press Start /Stop Button
i
n the
centre.
(Confirmed with a
single bleep
)
See
Diagram 13
Check that the outlet temperature increases to
a comfortable temperature.
Check for leaks.
Press
START/STOP
button to switch the unit
OFF (Confirm with
three audible short
bleeps
)
.
See Diagram 12
This completes the commissioning.
1
Audible Short
Bleep
Audible Short
Bleep
1
Audible Short
Bleeps
3
IMPORTANT!
This appliance is not intended for use by persons (including
children and the infirm) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their
safety.
Children should be supervised to ensure that they do not play with the appliance.
I
Warning!
Do Not Switch The Shower On If You Suspect It Of Being Frozen,
Wait Until You Are Sure That It Has Been Completely Thawed Out.
IMPORTANT NOTE!
Always use the
Start/Stop button to switch the shower
OFF.
If the ceiling isolator is used to stop the
shower running, without first pressing the
Stop
button, then the shower may go into
Over Temperature Shutdown the next time it
is used.
I