background image

13

Tripod Base 

(refer to diagram page 4)

The CXR880

TM

 can be operated with or without the Tripod base.  The base is 

ideal for outdoor squaring/layout as the Fine Adjustment Rotation knob (c)

is handy for aligning the vertical beams, also indoors it is particularly useful 

when using the laser for plumb alignment.  The Adjustable Feet (e) can be 

used to bring the laser into self levelling range with the aid of the Bubble 

Vial (b) when the laser with base is placed on the ground.  To remove the 

base place the Lock Switch (d) in the locked position and rotate the base off 

anti-clockwise.

Setting a Site Square and layout

The CXR880

TM

 has 4 vertical line all at 90 degrees to each other, this makes 

this laser ideal for setting Site Squares and general outdoor and indoor layout 

without the need to do a 3-4-5 calculation.
First place the CXR880

TM 

over the datum corner for the desired 90 degree 

square using the plumb down reference point.  Next align one of the vertical 

lines with one of the lengths by placing the receiver on it side at the far end 

of the line to the datum point. (remember turn on in line mode and select 

relevant range sensitivity see page 12)

Turn on all vertical lines, turn tilt off and select pulse mode (outdoor mode), 

rotate  the  body  of  the  laser  at  first  manually  then  with  the  fine  rotation 

knob until the receiver picks up the laser and the solid tone indicating level 

is heard. (sometimes its hard to get the laser beam exactly on the level 

solid tone due to the extreme accuracy of the receiver if you get within a 

millimetre or so that will be accurate enough for most jobs)

Take the receiver over to 90 degree line move the receiver side to side slowly 

until you pick up the line and again get the solid tone.  The point from the 

receiver to the datum point is the second length of the square and is at 90 

degrees to the first, your site square is done.

SITE SQUARES & LAYOUTS 

Summary of Contents for CXR880

Page 1: ......

Page 2: ...laser beam Do not disassemble the instrument or attempt to perform any internal servicing Repairs and service should be performed only authorised service centres of Redback Lasers This instrument com...

Page 3: ...imply align over your datum and using your included LRMulti Receiver in line mode you can quickly and accurately set up your site The CXR880 is also ideal for all types of internal fit out such as win...

Page 4: ...Window 2 Remote Sensor 3 Charging Socket and LED 4 Keypad page5 5 Plumb Down Output 6 5 8 11tpi Screw Thread 7 Battery Compartment Tripod Base a b c d e a 5 8 11tpi Screw Thread b Bubble Vial c Fine R...

Page 5: ...ntrol Power On Off Remote On Off Tilt Mode On Off default on a b c d e f g a Bubble Vial b LCD Levelling Display c LED Levelling Display d Line Rotate Mode Light e Speaker On Off f Power Line Rotate M...

Page 6: ...hipped Running rechargeable batteries completely flat will increase battery life The CXR880 can operate off mains by plugging the charger for indoor use only into the unit Remember the CXR880 can oper...

Page 7: ...R880 detects significant disturbance or movement that could effect the accuracy of your work the laser will Tilt stop working and the laser beams will flash to indicate this You will need to then re l...

Page 8: ...king the laser more usable indoors as a visible laser You can set the scan angle to 60o 30o 5o and 0o and shift the beam both left and right The Scan Mode can be operated by both the Control Panel on...

Page 9: ...al lines Pressing again will turn each set of lines off To use the lines outdoors with the LRMULTI receiver the lines need to be set into pulse mode this is done by pressing and holding the VY P butto...

Page 10: ...cated to the user Ideally locate the laser away from other workers and machinery to avoid any accidental disturbance to the laser Turn the laser on allow to level and begin rotating On either the cont...

Page 11: ...e laser along the X axis and hold the staff at this point slide the receiver up down the staff until the receiver indicates level see receiver instructions page 12 Then making a note of the height on...

Page 12: ...ine mode in fine mode indicated by the accuracy of level is at its highest with only small movements up or down by the receiver taking it off level In coarse mode there is more movement up and down al...

Page 13: ...datum corner for the desired 90 degree square using the plumb down reference point Next align one of the vertical lines with one of the lengths by placing the receiver on it side at the far end of th...

Page 14: ...rtified by one of our technicians here in Australia prior to despatch and should under normal conditions not go out of calibration A calibration certified sticker with the date and name of technician...

Page 15: ...utton on receiver Note the receiver does not work when the rotating beam is in scan mode Q When I try to move the line lasers the laser stops working A Tilt Mode may be activated so any movement of la...

Page 16: ...arranty CMI warrants that our products will be free from defects in material and workmanship for the warranty period CMI promises to repair or replace free of charge the product or part of product if...

Reviews: