background image

SINGLE PHASE POWER METER

Isolated V/I converter -RS485 Modbus - Datalogger

    QA-POWER-M

S

IN

G

L

E

 PH

AS

E

 POWE

R

 M

E

T

E

R

Iso

la

te

V/

I c

o

n

ve

rt

er 

-R

S4

8

5

 M

o

db

u

- D

a

ta

lo

g

g

er

Single-phase  power  meter

RMS

,

  and  Voltage/Current  Isolated.

Signal

Converter  1000  VDC  /  600  VAC

,

10  A  AC/DC

,

Variable  frequency

measurement

.

Configurable via USB

,

DIN rail mounting,

4 kV galvanic

isolation

,

  universal  supply  AC/DC.  Configurable  alarm  contact,

RS485

Modbus  and  Analog  output

.

DATALOGGING  via  USB

with  pen  drive

stick memory and download storage data on excel importable files.

RTC

Real Time Clock

 integrated.

INPUT

VOLTAGE

:

Up to

1000 V DC / 600 V AC

fully configurable via USB.

CURRENT:

Up to

10 A AC/DC

direct (more by using external CT).

1

01

2016

APPLICATION

Photovoltaic:

 parallel string voltage monitoring.

Energy Management:

direct communication via RS485 Modbus to

all Master Modbus devices.
High Voltage AC/DC converter.
High Current AC/DC converter using external CT.
Local and Remote monitoring at the same time.

OUTPUT

CURRENT

:

0...20 mA  programmable, max load 600 ohm.

VOLTAGE:

0...10 V programmable, min load resistence 2 kohm.

RS485  MODBUS

:

bus  connection  on  the  basis  of  the  module  or

terminal, dip-switch for setting address  and baudrate.

CONTACT  OUTPUT

:

  Optomos  contact,  programmable  NO  alarm

contact by free interface software FACILE QA-POWER, retransmission
or storage.

Q

A

-PO

WE

R

-M

Pen Drive USB Datalogger !

POWER SUPPLY

10..40 Vdc, 20-28 Vac, 50-60 Hz

ABSORPTION

Maximum 2.5 VA

PROTECTION INDEX

IP20

ACCURACY

WORKING FREQUENCY

DC or 1...400 Hz

TEMPERATURE COEFFICIENT

< 200 ppm/°C

WORKING TEMPERATURE

-15...+65°C

STORAGE TEMPERATURE

-40°C... +85°C

ISOLATION

  4  kV  input,  1.5  kV  between  output,

RS485 and power supply.

HUMIDITY

ALTITUDE

terminals, RS485 bus and Supply connection ready on the
base of module (connector not included, on request).

CONNECTIONS

Removable terminals 5.08 mm

CE STANDARDS

EN61000-6-4/2006 + A1 2011;
EN64000-6-2/2005;
EN61010-1/2010.

DIMENSIONS

17.5 x 100 x 112 mm (terminal excluded)

DATA LOGGER

Non-volatile memory. Log on USB OnTheGo port by Pen
Drive stick memory. RTC Real Time Clock integrated allows
you to manage the log with date and time.

CONFIGURATION

By free software FACILE QA-POWER-M to configure all of
the conversion parameters like span, zero,  alarm contact
and log via USB port or via RS485. Dip-switch for setting
modbus address and baudrate.

MOUNTING

DIN rail mounting with removable

Up to 2000 m s.l.m.

10...90% not condensing

MEASURE

0,5% F.S.

Irms, Vrms, Watt, Var, Va, Vpk, Ipk, Frequency,

Cosφ

, Energy bidirectional, THD

ENGLISH