PELLET STOVES
Chapter 4
red
INSTALLATION AND USE MANUAL
page
35
Operation
Technical service - Rights reserved - Reproduction prohibited
LED
SIGNALLING
TYPE OF PROBLEM
SOLUTION
Led -2
Led -1
Stove door open
Close the door
Led -1
Led 0
Pressure gauge
Draught difficulties or clogging of grate.
Check whether the grate is clogged by incrustation and
clean as required.
Control and if necessary clean the smoke duct and the air
intake.
Led 0
Led +1
Fuel loading door open
Close the door
Lower the pellet level in the hopper
4.19.
Shutdown mode due to alarm
When an alarm intervenes the stove will go into the automatic cooling
phase very similar to the "shutdown mode" to ensure the correct
cooling and automatic cleaning of the system.
If you wish to stop the acoustic signal while continuing the cooling
phase, simply press the button (
D
): after a brief period during which
the stove checks whether the cause that triggered the alarm has
subsided, the stove quits alarm mode.
The failed ignition and shutdown alarms can in most cases by
cancelled, that is by pressing button D again it is possible to go to a
new flame ignition phase (after having loaded pellets into the hopper).
Some alarms can be cancelled, others required the necessary
intervention of a specialised technician (previous table).