PELLET STOVES
Chapter 4
red
INSTALLATION AND USE MANUAL
page
31
Operation
Technical service - Rights reserved - Reproduction prohibited
POS.13
CAVO TERMOSTATO
AMBIENTE
To make the stove work according to the temperature set on the
external thermostat it is necessary to bring knob (
B)
to the minimum
position (15°C).
Please remember that once the temperature is reached, the stove does
not switch off but automatically modulates the flame and room fan to
minimum power. The stove will only switch off if the Eco-Stop function
is active.
4.14.
Operation with ECO-STOP
The
Eco-Stop
function automatically switches the stove off when the
room reaches a satisfactory temperature and switches the stove back
on again when room temperature drops.
Activation:
press the On/Off button briefly 5 times in a row within a
period of 6''. The card responds by sounding a long beep to confirm (3
seconds).
During operation with Eco-Stop active the green led remains
on for 5 seconds and switches off for 2 seconds, rather than
staying on permanently.
When the temperature is reached (satisfied temperature of
probe on the edge of the stove and (if present) external open
contact thermostat) the stove begins to the Eco-Stop count.
This prompts a gradual transition to Power level 1. The system
remains in this state until the counter reaches 20' and then, if
the temperature is still satisfactory, begins the switch off
process. On the other hand, if during these 20' the
temperature once again becomes unsatisfactory for a few
seconds (to exclude a momentary indication), the count
immediately zeros.
When Eco-Stop switches the stove off this is signaled by
orange and green leds flashing alternately every 2''.
ROOM THERMOSTAT
CABLE
POS.13