Problems/Causes/Solutions
Technical service - Rights reserved - Reproduction prohibited
PROBLEM
LED
POSSIBLE CAUSES
Solutions:
The pellets
accumulate in the
grate
Pellet load too high
Insufficient combustion area.
Pellets damp or unsuitable.
Door open
Smoke outlet blocked
Gaskets worn
Increase the pellet load
following the instructions in
section 4.10
Make sure that the
combustive air inlet in the
back of the stove is free
from obstructions or
blockages
Remove the unsuitable
pellet from the hopper and
exchange it with one
recommended by the
manufacturer
Check that the door is
properly closed
Clean the smoke outlet
Increase the smoke fan
speed according to the
technical manual
Replace the faulty
component
The flame is weak
and goes out
The pellet hopper is emptying
Low pellet load
Unsuitable pellet
Fill the hopper
Increase the pellet load
following the instructions in
section 4.10
Remove the unsuitable
pellet from the hopper and
exchange it with one
recommended by the
manufacturer
The room fan does
not stop
The stove is cooling down
Temperature probe faulty
Wait for the structure to
cool
Replace the faulty
component
The room fan is not
working
The temperature has not reached the
minimum ignition limit
The thermal protection has triggered
due to fan overheating
Fan faulty
Wait for the structure to
cool
Check for any
impediments in the fan
rotation
Replace the faulty
component
The room fan is not
regulated by knob A
The stove has reached the room temperature
set by knob B and automatically modulates at
minimum
Control panel faulty
Increase the temperature
set using knob B
Replace the faulty
component
The stove power is
not regulated by
knob C
The stove has reached the room temperature
set by knob B and automatically modulates at
minimum
Control panel faulty
Increase the temperature
set using knob B
Replace the faulty
component
No light signals on
the power supply
switch of the stove
The power supply cable is unplugged
The switch is not lit on I
No voltage
Fuse blown.
Connect the cable to the
socket plug
Ignite the stove using
switch I
Check the system
Replace the fuses
(section.4.4)