Security inspection according EN 16005
3
102-127108955
V1.1
14/ 102
Security inspection according EN 16005
Like the german standard DIN 18650, the EN 16005 describes the requirements and the test
methods for the safe use of power-operated pedestrian doors. The EN 16361 describes the
requirements for the production process and towards the documentation / classification of
the doors.
The EN 16005 is valid for automatic sliding, folding, swing and revolving doorsets. It does
not apply to high speed doors (Speedcord).
We recommend that you organize and use your country-specific version of the EN 16005.
Swing doorsets
Automatical swing doorsets must be provided with extra safety devices.
Protection during opening and closing cycles
The standard EN 16005 stipulates that a person must be detected on both sides of the door
during the closing cycle.
▪ The CA reference body (700 x 300 x 200 mm) must be detected at any point in an area
as wide as the doorway and extending over a distance of 200 mm on both sides of the
door axle.
▪ Devices to protect against the danger of crushing and impact between the door leaf and
the adjacent parts of the surroundings shall be provided during the opening and the clos-
ing cycles.
– presence sensors in the zone to be protected
– sufficient safety distances
– low energy movement
– activation mat
Solution:
Safety devices on the door leaf
Examples:
CEDES TOF/Taxi
BEA 4SAFE ON SW
3