Technical Data DFA 127
4
102-127108955
V1.1
20/ 102
Technical Data DFA 127
Dimensions:
Operator 600 x 85 x 124 mm (wxhxd)
Operating voltage:
230VAC, 50/60 Hz
Power consumption:
Standby 13 W, rated power 67 W
Max. torque:
50 Nm
Mass inertia:
65 kgm
2
Opening angle:
adjustable from 70° to 115°
Time delay:
adjustable from 0 to 60 seconds (40 steps)
Opening speed:
adjustable from 3 to 20 seconds (40 steps)
Closing speed:
adjustable from 5 to 20 seconds (40 steps)
Noise emission:
< 45 dB
Protection class:
IP20
Environment conditions
Temperature range:
-15° C bis +50° C
Humidity range:
up to 85% relative humidity, non condensing
Door leaf weights and door widths
The curves are calculated using the following formula:
J=1/3 x m x b
2
Standard arms:
J max. 65 kgm
2
Key:
J = mass moment of inertia kgm
2
Slide arms:
J max. 65 kgm
2
m = door leaf weight in kg
b = door leaf width in m
4
4.1
Summary of Contents for DFA 127
Page 98: ...Drawings 25 102 127108955 V1 1 98 102 Drawings Cable layout 25 25 1 ...
Page 99: ...Drawings 25 102 127108955 V1 1 99 102 ...
Page 100: ...Drawings 25 102 127108955 V1 1 100 102 Wiring diagram 25 2 ...
Page 101: ...Drawings 25 102 127108955 V1 1 101 102 ...