→ Interlock (two single-leaf swing
doors)
From software version 1.41, the DFA 127 allows the operation
of two single-leaf swing doors in interlock function with only
one BDE-D / BDI. One door can be opened only with AKI and
SSK when the other door is closed. An “OPEN” command is
saved by the closed door.
▪ The operating mode ‘Continuously open’ only opens
the appropriate door. For a complete opening of the
interlock area, e.g. to transport bulky goods, both
doors must be set to ‘Continuously open’.
▪ In manual mode, the door must be completely closed
again by hand. Only then the opposite door can open.
Consequently, this operating mode is not normally
recommended.
▪ All the usual DFA safety functions are also enabled in
‘Interlock’ mode.
▪ The use of direction-detecting trigger sensors is rec-
ommended to avoid needless opening movements.
→ Disabled
X No interlock function
→ All operating modes
The interlock function is only fully enabled in the operating
modes
‘Automatic’, ‘One-Way’ and ‘Locked’ . For the special
operating modes
‘Continuously open’ and ‘Manual’ the general
remarks stated above apply.
→ Only One-Way / Locked
The interlock function is only fully enabled in the operating
modes
‘One-Way’ and ‘Locked’ . In the operating mode ‘Auto-
matic’ both doors always open in the event of activation. For
the special operating modes
‘Continuously open’ and ‘Manual’
the general remarks stated above apply.