Page 19
Terminals Explained
Real Carriage Door & Sliding Hardware Copyright 2020© all rights reserved
Ter
-
mi
-
nal
Name
Descrip
-
tion
Default
Notes
78
FAULT 3 Safety
input
#3
FAULT
Re
-
quires
oppo
-
site re
-
lay state
from
SAFE 3
SAFE 2 and SAFE 3 can be programmed to perform
any of the following instructions under the “LOGIC”
sub-menu:
Range Value
Function
Description
000
PHOT
System reacts
to the input in
both opening
(stops) and
closing (revers
-
es) cycles
001
PHOT TEST
Same as
above. Re
-
quires the de
-
vice to super
-
vised (FAULT
active)
002
PHOT OP
System reacts
to the input
only during
the opening
cycle (stops)
003
PHOT OP TEST Same as
above. Re
-
quires the
device to be
supervised
(FAULT active)
004
PHOT CL
System reacts
to the input
only during the
closing cycle
(reverses)
005
PHOTO CL
TEST
Same as
above. Re
-
quires the
device to be
supervised
(FAULT active)
Range Value
Function
Description
006
BAR
Safety edge in
-
put. It reacts in
both opening
and closing. It
stops and par
-
tially reverses
007
BAR TEST
Same as
above. Re
-
quires the
device to be
supervised
(FAULT active)
008
BAR 8K2
Safety edge
input with
EOL resistor
as supervision
method. Only
active on SAFE
2
009
BAR OP
Safety edge
input. During
opening it
stops and par
-
tially reverses.
During closing
it stops
010
BAR OP TEST
Same as
above. Re
-
quires device
to be super
-
vised (FAULT
active)
011
BAR OP 8K2
Safety edge
with EOL resis
-
tor as supervi
-
sion method.
During open
-
ing it stops
and partially
reverses.
During closing
it stops. Active
only on SAFE 2
012
BAR CL
Safety edge
input. During
closing it stops
and partial
-
ly reverses.
During open
-
ing it stops.