Page 17
Terminals Explained
Real Carriage Door & Sliding Hardware Copyright 2020© all rights reserved
Range Value
for IC1 and IC2
Function
Description
004
PED
Pedestrian
opening.
Partially open
Motor 1 only
005
TIMER
Hold open
input
006
TIMER PED
Holds partially
open Motor 1
Accessory Connections
24-volt accessories and
peripherals can be powered
to terminals 50 and 51
Terminal
Name
Description
50
-24V
Accessory
power nega
-
tive common
51
+24V
Accessory
power positive
52
+24V -Safe
Positive power
when door is
not closed
Auxiliary Outputs
The Thalia board has two auxiliary outputs.
•
The first (20 and 21) is a 24-volt, courtesy light
output that will activate upon activation of the
door and will remain on for 90 seconds once
the door is closed
•
The second output labeled “Aux 3” (26 and
27) is a defaulted as a second channel radio
receiver output. This can be programmed to
perform any of the following functions under
“Logic” menu:
Range Value
for “Aux 3”
Function
Description
0
2nd channel
receiver output
Output
activate when
transmitter
activates the
2nd channel
1
Door open light
Output activate
when door is
not closed.
Flashes while
closing
2
Courtesy light
Output activate
during and for
90 seconds
after operation
3
Door not
closed
Output activate
until close limit
is reached
4
Start of cycle
Output activate
for 1 second at
the beginning
of each cycle
5
Door open
alarm
Output activate
if door is help
open for more
than double
the timer to
close time
6
Door running
Output active
while motors
are powered
7
Solenoid lock
Output
active for 2
seconds at the
beginning of
open cycle