When configured for digital switch detection an input channel can be used
to wake the router from low power mode. Refer to the Power management
page of the router’s web interface for settings.
The input channels are protected up to 32 V dc (in case of inadvertent
connection) and are opto isolated when driven from another device or supply.
The input channel will automatically switch between low voltage (0 V dc to
8 V dc) and High voltage (8 V dc to supply voltage). The two thresholds
are for the application of hysteresis.
Example connections
Example — Switch detection (Digital)
Example — Voltage monitor (Analog)
5.15 Output channel wiring
The router’s I/O channels 5 to 8 are output channels. The supplied output
cable (included in kit: R70800) must be used to connect automotive relays to
the router’s output connector.
Output cable signal wires
• White = Output 1 Normally open terminal (N/O)
• Black = Output 1 Common terminal (COM)
• Yellow = Output 2 Normally open terminal (N/O)
• Green = Output 2 Common terminal (COM)
• Purple = Output 3 Normally open terminal (N/O)
• Gray = Output 3 Common terminal (COM)
• Red = Output 4 Normally open terminal (N/O)
• Brown = Output 4 Common terminal (COM)
The output channels can be controlled from the YachtSense ™ Link web
interface or from the Raymarine app.
44