background image

5.6 Releasing the unit from the adaptor

Follow the steps below to release the unit from the Mounting adaptor.

1. Insert the flat of a small flat blade screw driver, or similar tool into the release hole located on

the flat edge of the mounting adaptor and twist the screw driver 90°, so that there is a small gap
between the Mounting trim and Mounting tray.

Important:

To help prevent scratching the product, cover the tip of your screw driver with a small

piece of insulation tape.

2. Twist the Mounting trim counter-clockwise approximately 10° and then lift away from the unit.

52

Summary of Contents for Micro-Talk E70361

Page 1: ...2015 Raymarine UK Limited 87265 2 Document number 04 2017 Date English en US INSTALLATION INSTRUCTIONS Micro Talk Gateway...

Page 2: ......

Page 3: ...ts design patents patents pending or design patents pending Fair Use Statement You may print no more than three copies of this manual for your own use You may not make any further copies or distribute...

Page 4: ......

Page 5: ...ion instructions 16 User manuals Print Shop 16 2 2 Product overview 17 Multiple data sources MDS 18 SeaTalkng 18 Micronet 18 2 3 Networking restrictions 19 Chapter 3 Planning the installation 21 3 1 I...

Page 6: ...the Riser 50 5 6 Releasing the unit from the adaptor 52 Chapter 6 System operation and setup 53 6 1 Transducer calibration 54 6 2 Autonetworking 55 Autonetworking compatible Micronet displays 55 Perf...

Page 7: ...11 2 SeaTalk ng cabling components 77 11 3 SeaTalk ng cables and accessories 78 Appendix A NMEA 2000 PGN support 81 7...

Page 8: ...8...

Page 9: ...ply greater than the specified maximum rating may cause permanent damage to the unit Refer to the Technical specification section for voltage rating Caution Power supply protection When installing thi...

Page 10: ...ipment Requirement for ferrites on non Raymarine cables If your Raymarine equipment is to be connected to other equipment using a cable not supplied by Raymarine a suppression ferrite MUST always be a...

Page 11: ...issions it may contain In addition our policy of continuous product improvement may change specifications without notice As a result Raymarine cannot accept liability for any differences between the p...

Page 12: ...12...

Page 13: ...hapter 2 Document and product information Chapter contents 2 1 Document information on page 14 2 2 Product overview on page 17 2 3 Networking restrictions on page 19 Document and product information 1...

Page 14: ...tated in this document However the core supplied product and its features will remain the same as those described in this document To ensure that you are using the correct documentation for your produ...

Page 15: ...y E70327 SeaTalkng power cable A06049 SeaTalkng backbone cable A06036 SeaTalkng 5 way block A06064 SeaTalkng terminator A06031 SeaTalkng T piece A06028 Advanced sailing kit T70342 T70349 Micro Talk E7...

Page 16: ...mentation that accompanies your display User manuals Print Shop Raymarine provides a Print Shop service enabling you to purchase a high quality professionally printed manual for your Raymarine product...

Page 17: ...eaTalkng to Micronet Pole Rail or Surface or Bracket mountable using optional mounting kits NMEA 2000 compliant Low power consumption 12 V dc operation 24V protection Waterproof to IPx6 and IPx7 The f...

Page 18: ...which compatible equipment connect using a spur Data and power are carried within the backbone Devices that have a low draw can be powered from the network although high current equipment will need to...

Page 19: ...ce s NMEA 0183 input output connections are NOT connected to an MFD or an NMEA 0183 to SeaTalkng converter that is connected to the same network as the gateway Multiple Micro Talk gateways It is recom...

Page 20: ...20...

Page 21: ...n checklist on page 22 3 2 Parts supplied on page 23 3 3 Software updates on page 24 3 4 Tools required for installation on page 25 3 5 Warnings and cautions on page 26 3 6 Selecting a location on pag...

Page 22: ...5 Drill cable and mounting holes 6 Make all connections into equipment 7 Secure all equipment in place 8 Power on and test the system Schematic diagram A schematic diagram is an essential part of plan...

Page 23: ...t SeaTalkng White cable 5 M4 x 40mm Threaded studs x 3 used for surface mounting 6 Finger nuts x 3 used for surface mounting Unpack your product carefully to prevent damage or loss of parts check the...

Page 24: ...sues with your product always follow the relevant update instructions carefully and in the sequence provided If in doubt as to the correct procedure for updating your product software refer to your de...

Page 25: ...2 4 mm 11 64 drill bit for fixing studs 3 22 mm for cable hole when surface mounting 4 Pozi drive screwdriver only required for Pole mount installations 5 Size 4 2 5 mm Hex Key only required for Pole...

Page 26: ...3 5 Warnings and cautions Important Before proceeding ensure that you have read and understood the warnings and cautions provided in the Chapter 1 Important information section of this document 26...

Page 27: ...nning the installation location also consider the following The unit should have a clear line of sight to the Micronet products it will connect to The range for unobstructed line of sight is up to 150...

Page 28: ...ion is required to ensure that EMC performance is not compromised Note In areas of extreme EMC interference some slight interference may be noticed on the product Where this occurs the product and the...

Page 29: ...3 7 Product dimensions Planning the installation 29...

Page 30: ...30...

Page 31: ...ables and connections Chapter contents 4 1 General cabling guidance on page 32 4 2 Connections overview on page 33 4 3 SeaTalkng power supply on page 35 4 4 Network examples on page 40 Cables and conn...

Page 32: ...and exposure to heat Use trunking or conduit where possible Do NOT run cables through bilges or doorways or close to moving or hot objects Secure cables in place using tie wraps or lacing twine Coil a...

Page 33: ...nections Connection Qty Connects to Suitable cables 1 1 SeaTalkng backbone 2 NMEA 2000 backbone 1 SeaTalkng spur cables 2 SeaTalkng to DeviceNet adaptor cable A06045 Can connect up to 32 Compatible Mi...

Page 34: ...clicks until it is in the locked position SeaTalkng product loading The number of products that can be connected to a SeaTalkng backbone depends on the power consumption of each product and the physic...

Page 35: ...rops when the engines are started 2 The ACU 100 and SPX 5 cannot be used to power the SeaTalkng backbone SeaTalkng power connection point Small systems If the backbone length is 60 m 197 ft or less th...

Page 36: ...with a different product See below for more information on implementation for some common power distribution scenarios Important When planning and wiring take into consideration other products in you...

Page 37: ...distribution panel Alternatively the SeaTalkng power cable may be connected to a suitable breaker or switch on the vessel s distribution panel or factory fitted power distribution point The distributi...

Page 38: ...standards BMEA Code of Practice for Electrical and Electronic Installations in Boats NMEA 0400 Installation Standard ABYC E 11 AC DC Electrical Systems on Boats ABYC A 31 Battery chargers and Inverte...

Page 39: ...plying power to this product ensure it has been correctly grounded in accordance with the instructions provided Warning Positive ground systems Do not connect this unit to a system which has positive...

Page 40: ...elow are provided as examples only Example system with wireless hull transmitter 1 Mast rotation sensor 2 Micronet Wind transducer 3 Micro Talk gateway 4 Wireless instrument 5 Heading source e g Evolu...

Page 41: ...8 SeaTalkng MFD 9 SeaTalkng 5 way block 10 DST transducer 11 Wireless hull transmitter Example system with SeaTalkng DST transducer 1 Mast rotation sensor 2 Micronet Wind transducer 3 Micro Talk gatew...

Page 42: ...4 Wireless instrument 5 Heading source e g Evolution EV sensor 6 SeaTalkng instrument 7 SeaTalkng Pilot Controller 8 SeaTalkng MFD 9 SeaTalkng 5 way block 10 DST transducer 42...

Page 43: ...5 2 Pole or rail mounting on page 45 5 3 Surface mounting using the Deck mounting kit on page 46 5 4 Bracket mounting using the Deck mounting kit on page 48 5 5 Surface mounting using the Riser on pag...

Page 44: ...l 3 x fixing holes and 1 x cable hole using drill bit sizes as indicated on the template 3 Place the waterproof gasket into position on the underside of the unit 4 Connect the cable to an available Se...

Page 45: ...nd pole or b the cable exit hole 3 Connect the cable to an available SeaTalk ng spur connection then connect the other end of the cable to the connector on the underside of the unit and secure using t...

Page 46: ...location requirements see 3 6 Selecting a location for details 1 Using the Mounting tray template 87170 drill 4 holes in the mounting surface plus a 22 mm 7 8 in hole for the SeaTalkng cable 2 Place t...

Page 47: ...nd secure by rotating the locking collar clockwise 2 clicks 6 Insert the unit into the mounting tray ensuring the tabs in the Mounting tray are slotted into the grooves around the edge of the unit 7 P...

Page 48: ...duct Ensure that the chosen location meets the product s location requirements see 3 6 Selecting a location for details 1 Use the Mounting bracket template 87170 to drill 3 pilot holes in the vertical...

Page 49: ...in the cable connector on the underside of the unit and secure by rotating the locking collar clockwise 2 clicks 6 Insert the unit into the mounting tray ensuring the tabs in the Mounting tray are sl...

Page 50: ...The Wall bracket is not required when using the Riser Ensure that the chosen location meets the product s location requirements see 3 6 Selecting a location for details 1 Use the supplied Deck mount r...

Page 51: ...Mounting tray 6 Pull the SeaTalkng cable through the Riser and Mounting tray Plug in the cable connector on the underside of the unit and secure by rotating the locking collar clockwise 2 clicks 7 Ins...

Page 52: ...e release hole located on the flat edge of the mounting adaptor and twist the screw driver 90 so that there is a small gap between the Mounting trim and Mounting tray Important To help prevent scratch...

Page 53: ...stem operation and setup Chapter contents 6 1 Transducer calibration on page 54 6 2 Autonetworking on page 55 6 3 Powering the unit on and off on page 59 6 4 Data damping on page 60 System operation a...

Page 54: ...is is particularly important with the Mast rotation device which must be linearized after and independently of your primary heading source This means 2 linearizations are required the first for the he...

Page 55: ...remote display Performing Autonetworking Follow the steps below to add new Micronet products to an existing system or create a new system from multiple boxes Note Autonetworking should be performed b...

Page 56: ...wer on the chosen display by pressing and holding the Down Power button for 2 seconds 5 Ensure the chosen display is not showing a Racer Timer or Wind Shift page 6 Press the Set Up button for 2 second...

Page 57: ...k follow the steps below i Press any button on a display that has JOIN flashing onscreen The Display will show JOIN YES ii Confirm by pressing any button on the same display The display will show DONE...

Page 58: ...ove them from the vessel 14 Ensure all units are working correctly before mounting them Product identification on Micronet The Micro Talk gateway is identified differently during the Autonetworking pr...

Page 59: ...Talk unit will automatically power on when power is applied to the SeaTalkng network that the unit is connected to Powering off The Micro Talk unit is powered off when the SeaTalkng network it is con...

Page 60: ...gs are set to either Slow Medium or Fast rather than Auto To determine whether you should make the damping changes on SeaTalkng or MicroNet the user should consider the other products in their network...

Page 61: ...Chapter 7 Troubleshooting Chapter contents 7 1 Troubleshooting on page 62 7 2 LED Diagnostics on page 63 Troubleshooting 61...

Page 62: ...oducts are subjected to comprehensive testing and quality assurance programs If you do experience problems with your product this section will help you to diagnose and correct problems in order to res...

Page 63: ...ne Red Micronet searching for network None Green Normal operation None Red SeaTalkng connection lost Micronet will revert to searching mode after 30 seconds 1 Power cycle unit 2 Check network connecti...

Page 64: ...64...

Page 65: ...Chapter 8 Maintenance Chapter contents 8 1 Service and maintenance on page 66 8 2 Routine equipment checks on page 67 8 3 Product cleaning on page 68 Maintenance 65...

Page 66: ...8 1 Service and maintenance This product contains no user serviceable components Please refer all maintenance and repair to authorized Raymarine dealers Unauthorized repair may affect your warranty 66...

Page 67: ...d that you perform the following routine checks on a regular basis to ensure the correct and reliable operation of your equipment Examine all cables for signs of damage or wear and tear Check that all...

Page 68: ...ghtly rinse or flush with clean cool fresh water If your product has a display screen do NOT wipe the screen with a dry cloth as this could scratch the screen coating Do NOT use abrasive acidic ammoni...

Page 69: ...Chapter 9 Technical support Chapter contents 9 1 Raymarine product support and servicing on page 70 9 2 Learning resources on page 72 Technical support 69...

Page 70: ...ir flir com Web support Please visit the Support area of the Raymarine website for Manuals and Documents http www raymarine com manuals FAQ Knowledgebase http www raymarine com knowledgebase Technical...

Page 71: ...Raymarine subsidiary Russia 7 495 788 0508 info mikstmarine ru Authorized Raymarine distributor Viewing product information With your MFD Homescreen displayed 1 Select Set up 2 Select Maintenance 3 Se...

Page 72: ...nge of in depth training courses to help you make the most of your products Visit the Training section of the Raymarine website for more information http www raymarine co uk view id 2372 FAQs and Know...

Page 73: ...Chapter 10 Technical specification Chapter contents 10 1 Technical specification on page 74 Technical specification 73...

Page 74: ...ting in the UK Europe or Africa 915 9 MHz for products operating in the USA Canada South America and Australia Environmental Installation environment Operating temperature 20 C to 55 C 4 F to 131 F St...

Page 75: ...Chapter 11 Spares and accessories Chapter contents 11 1 Accessories on page 76 11 2 SeaTalk ng cabling components on page 77 11 3 SeaTalk ng cables and accessories on page 78 Spares and accessories 75...

Page 76: ...1 Accessories The following accessories are available Accessories Item Part number Pole rail mounting adaptor kit A80370 6 m SeaTalkng white spur cable A06072 Deck mounting Clamshell Riser kit A80437...

Page 77: ...onnected Terminator Required at either end of the backbone Inline terminator Used to connect a spur cable directly to the end of a backbone useful for longer cable runs Spur cable Used to connect devi...

Page 78: ...2 SeaTalk ng 0 4 m 1 3 ft elbow spur A06033 SeaTalk ng 0 4 m 1 3 ft backbone A06034 SeaTalk ng 1 m 3 3 ft backbone A06035 SeaTalk ng 3 m 9 8 ft backbone A06036 SeaTalk ng 5 m 16 4 ft backbone A06068 S...

Page 79: ...n to SeaTalk ng adaptor cable 0 4 m 1 3 ft A06045 DeviceNet adaptor cable Female Allows the connection of NMEA 2000 devices to a SeaTalk ng system A06046 DeviceNet adaptor cable Male Allows the connec...

Page 80: ...80...

Page 81: ...nction 126464 Transmission PGN list 126464 Received PGN list 126992 System time 126993 Heartbeat 126996 Product information 126998 Configuration information 127237 Heading track control 127250 Vessel...

Page 82: ...82...

Page 83: ......

Page 84: ......

Page 85: ...nce 27 28 See also Compass safe distance L LED status 63 LEN See Load equivalency number See Load Equivalency Number Load equivalency number 35 Location requirements 27 Locking collar 34 M Maintenance...

Page 86: ...tection Surface mounting 44 46 50 System examples See Network examples T Technical support 70 Thermal breaker rating SeaTalkng 36 Tools 25 Troubleshooting 62 Typical systems See Network examples U Upg...

Page 87: ......

Page 88: ...www raymarine com Raymarine UK Limited Marine House Cartwright Drive Fareham PO15 5RJ United Kingdom Tel 44 0 1329 246 700...

Reviews: