3.1 Exhaust system requirements
Danger
Danger of emission of toxic gases, vapors or dust.
During laser operation, toxic aerosols may be produced.
– The laser system may be operated only with properly installed and operating exhaust
system.
– Check with the material manufacturer for its toxic effect.
Caution
The laser may only be operated with properly installed and operating exhaust system. Damage
to the system, caused by the use of not any exhaust system or improper extraction equipment,
will not be covered by any liability.
The following Trotec exhaust system meets the requirements:
•
Vent Set for R & Q 400: (230V, 50Hz, Euro Plug), (115V, 60Hz, US Plug)
•
or equivalent
The requirements for the exhaust system and recommended Trotec exhaust systems for standard
applications depend on the working table installed in the machine.
Notice
Connection has to be carried out by our Technical Support.
Observe instructions for operation and maintenance according to the operating manual of the
exhaust system.
The monitoring point for flow rate and pressure is at the exhaust port at the laser machine. Pressure loss
by hoses / pipes or filter parts of the exhaust system has to be determined and additionally calculated when
selecting a proper exhaust system.
A powerful exhaust system keeps the lifetime of optics and mechanical components, the cutting quality and
the laser power interacting with the workpiece from being impaired by fumes and dust accumulating in the
machine.
ENGLISH (Translation)
07/2021
29 / 83