Troubleshooting
10
Four Cycle Troubleshooting
The following is provided as a basic troubleshooting guide. Its use requires a complete review of all conditions
and symptoms. Always examine the exterior for clues: leaks, excessive dirt, or obvious damage. Some repairs will
require the assistance of a
Rayco Dealer
.
Should more extensive repair be needed, we recommend you contact a local
Rayco Dealer
for repair. Repair manuals are also available from your local dealer or direct from www.TecumsehPower.com. A
complete list of the available manuals can be found at the end of this book.
NOTE:
Refer to Technician's Handbook for a more detailed list of remedies.
Preparation
Before troubleshooting any system problem, see instructions.
Make your troubleshooting easier by preparing as follows:
•
Work in a clean, well-lighted place.
•
Keep proper tools and materials nearby.
•
Keep an adequate supply of clean petroleum-based solvent.
To reduce the risk of serious injury or death from fires and/or explosions, NEVER use flammable
solvents (e.g., gasoline) to clean serviceable parts. Use a water-based, non-flammable solvent
Degreaser Cleaner.
NEVER use compressed air to clean debris from yourself or your clothing. When using compressed
air to clean or dry serviceable parts:
• Wear appropriate eye protection.
• Use only approved air blow nozzles.
CAUTION
FUEL SYSTEM
Engine Will Not Start
Check if spark plug is wet or
dry
Wet
Dry
Defective spark plug
Use Tester 670366
Review with the customer proper
priming procedure (3-5 primes,
waiting 2 seconds between each
prime)
Restricted air filter
If equipped with a choke, check for full
travel. Check throttle cable and control
for proper adjustment.
Improper or stale fuel
Check fuel supply and fuel cap vent
Exhaust ports plugged
Restriction in fuel system (filter)
Carburetion problems due to flooding,
over priming, etc.*
Carburetion problem*
(bad bowl gasket)
Ignition System
Poor Compression
• Air pressure must not exceed 30psi (206kPa).
• Shield yourself and bystanders from flying debris.
Summary of Contents for RG25HD
Page 48: ...RG25DH Operation Service Maintenance Parts Manual 48 Troubleshooting ...
Page 49: ...RG25DH Operation Service Maintenance Parts Manual 800 392 2686 49 Troubleshooting ...
Page 50: ...RG25DH Operation Service Maintenance Parts Manual 50 Troubleshooting ...
Page 51: ...RG25DH Operation Service Maintenance Parts Manual 800 392 2686 51 Troubleshooting ...
Page 52: ...RG25DH Operation Service Maintenance Parts Manual 52 Troubleshooting ...
Page 53: ...RG25DH Operation Service Maintenance Parts Manual 800 392 2686 53 Troubleshooting ...
Page 54: ...RG25DH Operation Service Maintenance Parts Manual 54 Troubleshooting ...
Page 55: ...RG25DH Operation Service Maintenance Parts Manual 800 392 2686 55 Troubleshooting ...
Page 56: ...RG25DH Operation Service Maintenance Parts Manual 56 Troubleshooting ...
Page 57: ...RG25DH Operation Service Maintenance Parts Manual 800 392 2686 57 Troubleshooting ...
Page 66: ...RG25DH Operation Service Maintenance Parts Manual 66 Hydraulic Drive Assembly ...