CHAPTER 6
50
SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual
INJECTION PUMP PRESSURE TRANSDUCER
To replace the pressure transducer (P/N 422-0000-090):
1. Disable and shutdown any automatic product control features of the Sidekick Pro injection system and turn off
the vehicle when replacing the pressure transducer assembly.
2. Disconnect the pressure transducer connector on the top of the pressure transducer body. Be careful to keep
dust, debris, or liquid chemicals which may seep from the injection pump head from contaminating the cable
connection.
3. Loosen the pressure transducer while securing the connected fitting to prevent damage to the pump head.
4. Apply RectorSeal
®
or equivalent thread sealant to the new pressure transducer and thread into the pump
head.
5. Tighten the pressure transducer body to secure the pressure transducer.
NOTE:
Do not over tighten the pressure transducer. Over tightening the pressure transducer may damage
the pump head.
WARNING
Always use caution when performing
maintenance or servicing an injection pump or
system which has been previously pressurized.
Wear appropriate protective equipment to
prevent contact with hazardous chemicals and
rinse the chemical system as instructed by the
chemical manufacturer prior to performing
maintenance.
WARNING
Hazardous chemicals may be under pressure
even if the pump has not been in service recently.
Before replacing any components on the
injection pump, thoroughly rinse the injection
pump with clean water to remove excess
chemical residue.