SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual
TABLE 3.
System Settings Page Information
ALARMS SETTINGS
1. Open the UT Menu and select the desired Sidekick Pro™ ICD Menu icon.
2. Select Alarms Settings. The following information will display:
TABLE 4.
Alarms Information
Display
Additional Setting Information
Preset Rate Values
Use the rate presets to set three target rate settings. With preset rate
values set, the operator may to quickly select a different target rate by
selecting the rate preset buttons on the run screenn while operating in
the field.
Rate Bump
Sets the increment by which either the target rate will increase or
decrease when using the bump during an active application.
Rate Selection
Use the drop-down list to select the method for changing the injected
product target rate on the run screen and home pages.
Display Smoothing
Enable this option to allow the system to smooth fluctuations in the
application rate displayed. If the actual monitored rate is within 10% of
the target rate, the target rate will be displayed as the actual rate.
Alarms
Description
DI Efficiency Limit
The minimum allowable efficiency for the DI pump. Typical values range
from 60 - 99%. Alarm will trigger if actual efficeincy is below the limit for
10 seconds. Higher efficiency values may cause alarms to trigger more
often, lower efficiency values may not trigger the alarm.
Off Rate Limit
The allowable difference between the target and actual product
application rates. If the difference between the actaul and target rate
exceeds the set percentage for more than five seconds, the system will
display an off rate alarm.
Low Tank Limit
The volume at which the low injection chemical supply tank alarm will
activate. Enter a value of zero or deselect enablee to disable the low tank
alarm.
Pop Up Alarms
Pop Up Alarms are used to notify the user of system erros by displaying
an alarm on the home screen.
High Inlet Vacuum
Notifies the user that the maximum pump inlet vacuum has been
exceeded. There may be a restriction in the plumbing between the
injection pump inlet and the direct injection chemical supply tank.