Calibration and Operation: Sidekick Pro™ ICD Menu
33
CALIBRATION AND OPERATION
TABLE 2.
System Settings Page Information
RATE SETTINGS
1. Open the UT Menu and select the desired Sidekick Pro™ ICD Menu button.
2. Press the Product Setup button.
3. Select the Rate Settings tab. The following information will display:
NOTE:
The following Rate Settings options will only be displayed when connected to a rate per area device.
Display
Additional Setting Information
Tank Capacity
Displays the capacity of the direct injection chemical supply tank in
gallons (US) or liters (SI).
Tank Level
Displays the volume of product currently in the injection chemical supply
tank. This volume is used to calculate the volume remaining in the tank
and for the low tank alarm if enabled.
Flow Correction
Used to adjust the actual amount pumped by the injection pump for a
given target amount. A positive value will increase the amount pumped. A
negative value will decrease the amount pumped. If the volume caught
during a catch test or pumped during normal operation is less than the
desired volume pumped, increase the Flow Correction% by the%
difference. If the volume caught is greater than the desired volume
pumped, decrease the Flow Correction% by the % difference. Typical
error should be no more than ±3%.
Function Instance
Number
Each Sidekick Pro injection pump connected to an ISOBUS system will
have a unique number from 1 to 8 assigned.
Agitator Duty Cycle
This displays the amount of time during a ten minute cycle the agitator is
on. For example, a 20% duty cycle would turn on the agitator for two
minutes and off for eight minutes.
Agitator Equipped
Enables the agitator feature. Check the box to enable the feature if
agitation is required and the system is equipped with the direct injection
chemical supply tank agitation system.
Rinse Assist Equip
Enables the rinse assist feature. Check the box to enable the feature if the
injection system is equipped with the direct injection automated rinse
system.
Sidekick Pro
ICD Menu
Product
Setup
Rate Settings