61
REMOTE COMPUTER TO CASE IH SCS 4600 CONSOLE
All request strings begin with $R, to indicate a Raven communication string.
Rate 1 Change Request:
To set Rate Cal values for all three products:
$R,RC,<rate_1_cal>,<rate_2_cal>,<rate_3_cal><CR><LF>
To set Rate Cal values for products 1 and 3 only:
$R,RC,<rate_1_cal>,,<rate_3_cal><CR><LF>
Calibration String Values Request:
$R,CR<CR><LF>
Data String Request:
$R,DR<CR><LF>
CASE IH SCS 4600 CONSOLE TO REMOTE COMPUTER
All console output strings begin with $R171-, the $R indicates a Raven communication string, the 171 is
the last three digits of the CASE IH SCS 4600 program number and "-" denotes the software revision letter.
Calibration Strings:
$R171-,C1,<switch_byte_1>,<switch_byte_2>,<boom_1_cal>,
<boom_2_cal>,<boom_3_cal>,<boom_4_cal>, <boom_5_cal>,
<boom_6_cal>,<boom_7_cal>,<boom_8_cal>,<boom_9_cal>,
<boom_10_cal>,<speed_cal><CR><LF>
$R171-,C2,<meter_1_cal>,<meter_2_cal>,<meter_3_cal>,0,0,<spreader_constant_1>,
<spreader_constant_2>,<spreader_constant_3>,0,0<CR><LF>
$R171-,C3,<valve_cal>,<valve_2_cal>,<valve_3_cal>,0,0,<rate_1_cal>,
<rate_2_cal>,<rate_3_cal>,0.0,0.0<CR><LF>
Bit
Switch Byte 1
Switch Byte 2
Switch Byte 3
0
boom 1
boom 8
prod 3 auto
1
boom 2
boom 9
prod 3 manual
2
boom 3
boom 10
0
3
boom 4
prod 1 auto
0
4
boom 5
prod 1 manual
0
5
boom 6
prod 2 auto
0
6
boom 7
prod 2 manual
0
7
1
1
1
Data Strings:
$R171-,D1,<total_area_1>,<total_area_2>,<total_area_3>,0.0,0.0,<field_area_1>,
<field_area_2>,<field_area_3>,0.0,0.0<CR><LF>
$R171-,D2,<total_volume_1>,<total_volume_2>,<total_volume_3>,0,0,
<field_volume_1>,<field_volume_2>,<field_volume_3>,0,0<CR><LF>
$R171-,D3,<tank_1_volume>,<tank_2_volume>,<tank_3_volume>,0,0,<miles/km>,
<feet/meters><CR><LF>
$R171-,D4,<speed>,<pressure1_1>,<pressure1_2>,<pressure1_3>,0,0,
<pressure2_1>,<pressure2_2>,<pressure2_3>,0,0<CR><LF>
Actual Rate:
$R171-,AR,<actual_rate_1>,<actual_rate_2>,<actual_rate_3>,0.0,0.0<CR><LF>
Time/Date:
$R171-,TD,<hr:min>,<month/day/year>,<field_reference><CR><LF>
APPENDIX 11
CASE IH SCS 4600 COMMUNICATION STRINGS
NOTE:
If prod auto and manual are both zero, the product is in Off.
For switch Byte Bits: 0 = Off and 1 = On.
Summary of Contents for SCS 4600
Page 1: ...Operators Manual SCS 4600 SCS 4600 SCS 4600 SCS 4600 SCS 4600...
Page 10: ...5 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 11: ...6 SECTION 1 LIQUID AND GRANULAR APPLICATIONS LIQUID AND GRANULAR APPLICATIONS...
Page 15: ...10 FIGURE 3 BATTERY CONNECTIONS LIQUID AND GRANULAR APPLICATIONS...
Page 34: ...29 FIGURE 6...
Page 37: ...32 GRANULAR APPLICATIONS SECTION 2 GRANULAR APPLICATIONS...
Page 38: ...33 FIGURE 7...
Page 44: ...39 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 45: ...40 CAN APPLICATIONS SECTION 3 CONTROLLER AREA NETWORK CAN...
Page 47: ...42 CAN APPLICATIONS FIGURE 13 FIGURE 14...
Page 48: ...43 FIGURE 15...