16
LIQUID AND
GRANULAR
APPLICA
TIONS
CONSOLE PROGRAMMING
When entering data into the Console, the entry sequence is always the same.
NOTE:
DATA MUST BE ENTERED INTO KEYS 3 THRU 7.
Complete the entry by again de-
pressing the ENTER key.
Depress the keys corresponding
to the number you wish to enter
(i.e. "2","1","2","3"). The numbers
will be displayed as they are en-
tered.
Depress the key in which
you wish to enter data.
Depress the ENTER key. An "E"
will illuminate in the display.
1.
INITIAL CONSOLE PROGRAMMING
When Console power is turned on, after all installation procedures have been completed, the
Console will flash
CAL
and
display ACRE US
. This means the console must be "calibrated", or
programmed, before it can be operated. This is a one-time operation which does not have to be
repeated. Turning OFF the POWER ON/OFF switch does not affect the Console memory. All data
is retained.