48
21)
COMPACT FLASH CARD NOT
RECOGNIZED.
22)
DISPLAY READS "LOOKING FOR
DATA TO FLASH IC WITH"
23)
LCD CONTRAST IS TOO DARK
OR TOO LIGHT
24)
CONSOLE DISPLAYS
"CHECK CAN NODES OR
CAN COMMUNICATION"
25)
CONSOLE DISPLAYS "CHECK
CONTROL NODE x" (where x refers
to 1, 2, or 3)
1)
Reboot console.
2)
Replace compact flash card.
3)
Return console to dealer for service.
1)
Console was put into program update mode.
Unhook cable from console, wait 30
seconds, and reboot console. Wait for
program to be restored.
1)
To lighten LCD contrast, hold key [1]. After
one second, contrast will begin to lighten
until key [1] is released.
2)
To darken LCD contrast, hold key [2]. After
one second, contrast will begin to darken
until key [2] is released.
3)
LCD contrast can also be adjusted from the
Console Menu within the Data Menu.
1)
If no CAN nodes are attached to the CAN
bus, press [DATA MENU] key. CAN menu
will appear and CAN node options will
automatically be shut off. Operation can
then be resumed as normal.
2)
Verify that CAN nodes and console are
connected to the CAN bus and that the
cabling between them is connected and in
tact.
3)
Verify that terminators are placed at both
ends of the CAN bus.
4)
Verify that CAN nodes have logic power and
ground are properly connected and energized
and no fuses are blown on power leads.
5)
Verify that CAN power adapter "T" cable is
plugged in at the front of the CAN bus and
12V switched power is applied to the bus.
6)
Reboot the console.
7)
Contact service technician for CAN system
repair.
1)
If Product Control Node x is not connected to
the CAN bus, press [DATA MENU] key. CAN
menu will appear and CAN node options can
be toggled ON and OFF using the [CE] key.
Operation can then be resumed as normal.
2)
Verify that Product Control Node x is
connected to the CAN bus.
3)
Verify that Product Control Node x has logic
power and ground properly connected and
energized and no fuses are blown on power
leads.
4)
Verify that CAN bus cabling from the console
to the node is connected and in tact.
Summary of Contents for SCS 4600
Page 1: ...Operators Manual SCS 4600 SCS 4600 SCS 4600 SCS 4600 SCS 4600...
Page 10: ...5 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 11: ...6 SECTION 1 LIQUID AND GRANULAR APPLICATIONS LIQUID AND GRANULAR APPLICATIONS...
Page 15: ...10 FIGURE 3 BATTERY CONNECTIONS LIQUID AND GRANULAR APPLICATIONS...
Page 34: ...29 FIGURE 6...
Page 37: ...32 GRANULAR APPLICATIONS SECTION 2 GRANULAR APPLICATIONS...
Page 38: ...33 FIGURE 7...
Page 44: ...39 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 45: ...40 CAN APPLICATIONS SECTION 3 CONTROLLER AREA NETWORK CAN...
Page 47: ...42 CAN APPLICATIONS FIGURE 13 FIGURE 14...
Page 48: ...43 FIGURE 15...