Troubleshooting: General Troubleshooting
71
TROUBLESHOOTING
Total volume does not register or registers
flow inaccurately.
• Check flow meter/encoder cable for breaks and shorts. See the
Cable Troubleshooting section on page 58.
• Check the internal components of the flow meter; clean and
adjust. Appendix D, Maintenance Schedule and Replacement
Parts
for flow meter cleaning and adjustments.
• Replace flow meter transducer/encoder.
• Verify that arrow on flow meter is pointing in direction of flow.
• Verify the flowmeter calibration value and units and adjust as
necessary. Refer to the Flowmeter Cal section on page 24 for
additional flowmeter calibration information.
Boom valve(s) will not operate.
• Check cable for wires with breaks.
• Verify the switches and boom valves are mapped correctly.
• Check connectors for cleanliness.
• Check BOOM switch and MASTER switch for operation.
• Replace boom valves.
Pressure inaccurate or unstable.
• Verify the correct pressure for the transducer is selected.
• In Pressure Settings, lower the Response Rate to stabilize the
system.
• Verify the pressure on UT matches separate external mechanical
gauge.
Individual nozzle will not communicate
with Raven Service Tool Action
• Verify power to the nozzle.
• Verify the NCV cable connection voltages fall within the desired
range.
• Cycle power to the system.
• Recalibrate the system.
• Replace the NCV.
Cannot detect BLE (Blue-tooth low energy)
device for diagnostics
• Verify Bluetooth functionality is turned on for mobile device.
• Verify another mobile device isn’t already connected to the
Product Controller II ECU.
• Verify that the mobile device is BLE compatible running ISO
version 8.1 or newer or Android Version 5 or newer.
• Verify the mobile device is within line of sight to the Product
Controller II ECU.
Cannot connect to BLE (Blue-tooth low
energy) device for diagnostics
• Verify mobile devices is within line of sight to the Product
Controller II ECU.
• Verify device Wireless ID on Product Controller II ECU System
Information screen.
• Verify a Device Passcode entered into mobile device matches
passcode shown on System Alert.
Problem
Action
Summary of Contents for ISO Product Controller II
Page 10: ...CHAPTER 1 viii ISO Product Controller II and Hawkeye Operation Manual...
Page 16: ...CHAPTER 1 6 ISO Product Controller II and Hawkeye Operation Manual...
Page 22: ...CHAPTER 2 12 ISO Product Controller II and Hawkeye Operation Manual...
Page 50: ...CHAPTER 4 40 ISO Product Controller II and Hawkeye Operation Manual...
Page 92: ...APPENDIX A 82 ISO Product Controller II and Hawkeye Operation Manual...
Page 95: ...P N 016 0171 584 H 85 FIGURE 3 Generic Cabling for Self Propelled Sprayer...
Page 97: ...P N 016 0171 584 H 87 FIGURE 5 Generic Cabling for Pull Type Sprayer with Existing Raven CAN...
Page 99: ...P N 016 0171 584 H 89 FIGURE 7 20 Spacing Generic Cabling...
Page 111: ...P N 016 0171 584 H 101...
Page 112: ...APPENDIX D 102 ISO Product Controller II and Hawkeye Operation Manual...
Page 116: ...APPENDIX E 106 ISO Product Controller II and Hawkeye Operation Manual...
Page 120: ...APPENDIX F 110 ISO Product Controller II and Hawkeye Operation Manual...
Page 128: ...APPENDIX G 118 ISO Product Controller II and Hawkeye Operation Manual...
Page 134: ...APPENDIX H 124 ISO Product Controller II and Hawkeye Operation Manual...