Hawkeye® Nozzle Control and Sidekick Pro ICD Setup: Tools Menu Settings Definitions
33
HAWKEYE® NOZZLE CONTROL AND SIDEKICK PRO ICD SETUP
MAX PUMP PWM
Enter a maximum pump PWM to set the maximum desired output for a pump controlled by a pulse width
modulated (PWM) hydraulic control valve. This setting limits how far the PWM valve will open. The maximum
operating pressure of the Hawkeye
®
nozzles is 80 PSI.
With the machine section and master switches in the on position, increase this value until the maximum desired
pressure is reached in a liquid system.
STANDBY PUMP PWM PERCENT
Enter the desired pump PWM duty cycle percent when all sections are off. This is utilized when standby pressure
control is not available (direct injection with a carrier check valve is installed). The default value is 42%.
PUMP PWM FREQUENCY
Used to set the coil frequency of the PWM valve (default is 60 Hz). Refer to the PWM control valve manufacturer
specifications for recommended PWM frequency.
MINIMUM NOZZLE PWM PERCENT
Enter a minimum PWM percent to set the minimum desired output (zero point or shutoff point) for the Hawkeye
®
nozzle control valves. With the machine master switch in the on position, decrease this value until the minimum
desired spray pattern is reached in the liquid system. The default value is 25%.
NOTE:
To help avoid under application or skips in coverage, review “Avoiding Skips with Hawkeye Nozzle
Control System” on page 73, and maintain the recommended application conditions.
FLOWMETER CALIBRATION VALUE AND UNITS
Enter the calibration value for the flow meter used to monitor the Hawkeye
®
system product flow. The flowmeter
calibration value and units are on the tag attached to the system flowmeter. Select the appropriate units for the
flowmeter calibration to ensure proper application system calibration information.
Raven flow meters use a meter cal in pulses per 10 gallons [37.9 L].
RESPONSE SENSITIVITY
The response sensitivity controls how sensitive the system is to changes in pressure, flow, and speed. Decrease if
the system pressure and rate oscillate slightly. Increase sensitivity if control is unresponsive. Avoid setting response
rate and sensitivity above 70.
DEADBAND
Sets the allowable tolerance between the target rate and the actual application rate. Enter a value between 1 and
9. A value of 1 equals a ±1% tolerance between the target and actual application rates where a value of 9 equals a
±9% tolerance. Default product control deadband is 1%.
CAUTION
Operating at an insufficient nozzle PWM percent
may result in under application or skips in
coverage.
Summary of Contents for ISO Product Controller II
Page 10: ...CHAPTER 1 viii ISO Product Controller II and Hawkeye Operation Manual...
Page 16: ...CHAPTER 1 6 ISO Product Controller II and Hawkeye Operation Manual...
Page 22: ...CHAPTER 2 12 ISO Product Controller II and Hawkeye Operation Manual...
Page 50: ...CHAPTER 4 40 ISO Product Controller II and Hawkeye Operation Manual...
Page 92: ...APPENDIX A 82 ISO Product Controller II and Hawkeye Operation Manual...
Page 95: ...P N 016 0171 584 H 85 FIGURE 3 Generic Cabling for Self Propelled Sprayer...
Page 97: ...P N 016 0171 584 H 87 FIGURE 5 Generic Cabling for Pull Type Sprayer with Existing Raven CAN...
Page 99: ...P N 016 0171 584 H 89 FIGURE 7 20 Spacing Generic Cabling...
Page 111: ...P N 016 0171 584 H 101...
Page 112: ...APPENDIX D 102 ISO Product Controller II and Hawkeye Operation Manual...
Page 116: ...APPENDIX E 106 ISO Product Controller II and Hawkeye Operation Manual...
Page 120: ...APPENDIX F 110 ISO Product Controller II and Hawkeye Operation Manual...
Page 128: ...APPENDIX G 118 ISO Product Controller II and Hawkeye Operation Manual...
Page 134: ...APPENDIX H 124 ISO Product Controller II and Hawkeye Operation Manual...