C
HAPTER
8
66
ISO Product Controller II and Hawkeye Operation Manual
523090
.1
Nozzle calibration error (single)
1. Restart the calibration wizard to recalibrate
the nozzle control system.
2. Cycle system power.
3. Reset defaults.
523091
.1
Nozzle calibration error
(multiple)
1. Restart the calibration wizard to recalibrate
the nozzle control system.
2. Cycle system power.
3. Reset defaults.
523092
.31
No tip information entered for
nozzle control valve (single)
1. Select the appropriate tip type. Refer to
Injection Pump Efficiency section on page 46
for additional assistance.
2. Restart the calibration wizard to reset the tip
type setting for the nozzle control system.
523093
.31
No tip information entered for
nozzle control valves (multiple)
1. Restart the calibration wizard to configure tip
information for the Hawkeye
®
nozzle control
valves.
523126
.13
Unable to detect Hawkeye
®
Product Controller II ECU
orientation
1. Check the Product Controller II ECU mounting
position and verify the Product Controller II
ECU is securely mounted.
2. Recalibrate the Product Controller II ECU gyro.
523136
.16
Monitored flow rate is higher
than the target rate deadband
1. Reduce the equipment speed.
2. Review “Avoiding Skips with Hawkeye Nozzle
Control System” section on page 73.
3. Refer to the Hawkeye Upper Home Screen
section on page 44 for assistance with setting
or adjusting the target rate.
4. Refer to the System Settings Tab - Alarm
section on page 30 for assistance with setting
or adjusting the off rate percent.
.18
Monitored flow rate is lower than
the target rate deadband
1. Increase the equipment speed.
2. Refer to the Hawkeye Upper Home Screen
section on page 44 for assistance with setting
or adjusting the target rate.
3. Refer to the System Settings Tab - Alarm
section on page 30 for assistance with setting
or adjusting the off rate percent.
523137
.18
Minimum flow not met
1. Activate product pump.
2. Review “Avoiding Skips with Hawkeye Nozzle
Control System” section on page 73.
3. Increase pump output to maintain the
minimum recommended flow rate for each
nozzle control valve.
Code ID
Description
Recommended Actions
Summary of Contents for ISO Product Controller II
Page 10: ...CHAPTER 1 viii ISO Product Controller II and Hawkeye Operation Manual...
Page 16: ...CHAPTER 1 6 ISO Product Controller II and Hawkeye Operation Manual...
Page 22: ...CHAPTER 2 12 ISO Product Controller II and Hawkeye Operation Manual...
Page 50: ...CHAPTER 4 40 ISO Product Controller II and Hawkeye Operation Manual...
Page 92: ...APPENDIX A 82 ISO Product Controller II and Hawkeye Operation Manual...
Page 95: ...P N 016 0171 584 H 85 FIGURE 3 Generic Cabling for Self Propelled Sprayer...
Page 97: ...P N 016 0171 584 H 87 FIGURE 5 Generic Cabling for Pull Type Sprayer with Existing Raven CAN...
Page 99: ...P N 016 0171 584 H 89 FIGURE 7 20 Spacing Generic Cabling...
Page 111: ...P N 016 0171 584 H 101...
Page 112: ...APPENDIX D 102 ISO Product Controller II and Hawkeye Operation Manual...
Page 116: ...APPENDIX E 106 ISO Product Controller II and Hawkeye Operation Manual...
Page 120: ...APPENDIX F 110 ISO Product Controller II and Hawkeye Operation Manual...
Page 128: ...APPENDIX G 118 ISO Product Controller II and Hawkeye Operation Manual...
Page 134: ...APPENDIX H 124 ISO Product Controller II and Hawkeye Operation Manual...