Troubleshooting: Diagnostic Trouble Code (DTC) List
67
TROUBLESHOOTING
523192
.13
Sparge pressure transducer not
calibrated
1. Refer to the “Tools Menu Settings Definitions”
on page 22 for assistance with pressure
transducer calibration.
.14
New injection pump detected
1. A new injection pump was detected.
.15
Injection pump lost
communication
1. Verify the LED’s on the injection pump are on.
2. Check the CAN connections of the injection
device.
3. Connect the Raven Service Tool to the
ISOBUS and verify communication.
523193
.16
High system efficiency
1. Check the plumbing system for leaks.
2. Check the pressure transducer calibration.
3. Check the Flowmeter Calibration value.
4. Verify the fencerow outputs are not active.
5. Check the NCV’s for debris or seal for wear.
.18
Low system efficiency
1. Check the pressure transducer calibration.
2. Check the Flowmeter Calibration value.
3. Check the NCV’s for debris or seal
deformation.
523520
.31
Invalid flowmeter calibration
1. Enter a valid flowmeter calibration value.
523906
.17
Equipment speed below the
speed range (single nozzle)
1. Increase equipment speed to the range
displayed on the Hawkeye home screen. Refer
to the Hawkeye Upper Home Screen section
on page 44 and Hawkeye Lower Home
Screen section on page 47 for assistance with
the information provided on the home
screen.
523907
.17
Equipment speed below the
speed range (multiple nozzles)
1. Increase equipment speed to the range
displayed on the Hawkeye home screen.
523908
.15
Equipment speed above the
speed range (single nozzle)
1. Reduce equipment speed to the range
displayed on the Hawkeye home screen.
523909
.15
Equipment speed above the
speed range (multiple nozzles)
1. Reduce equipment speed to the range
displayed on the Hawkeye home screen. Refer
to the Hawkeye Upper Home Screen section
on page 44 and Hawkeye Lower Home
Screen section on page 47 for assistance with
the information provided on the home
screen.
523910
.31
Nozzle power/temperature error
(single)
1. Check for clogs in valve or associated
plumbing that may be preventing liquid flow
through the valve.
523911
.31
Nozzle power/temperature error
(multiple)
1. Check for restrictions in valves or associated
plumbing that may be preventing liquid flow
through the valve.
Code ID
Description
Recommended Actions
Summary of Contents for ISO Product Controller II
Page 10: ...CHAPTER 1 viii ISO Product Controller II and Hawkeye Operation Manual...
Page 16: ...CHAPTER 1 6 ISO Product Controller II and Hawkeye Operation Manual...
Page 22: ...CHAPTER 2 12 ISO Product Controller II and Hawkeye Operation Manual...
Page 50: ...CHAPTER 4 40 ISO Product Controller II and Hawkeye Operation Manual...
Page 92: ...APPENDIX A 82 ISO Product Controller II and Hawkeye Operation Manual...
Page 95: ...P N 016 0171 584 H 85 FIGURE 3 Generic Cabling for Self Propelled Sprayer...
Page 97: ...P N 016 0171 584 H 87 FIGURE 5 Generic Cabling for Pull Type Sprayer with Existing Raven CAN...
Page 99: ...P N 016 0171 584 H 89 FIGURE 7 20 Spacing Generic Cabling...
Page 111: ...P N 016 0171 584 H 101...
Page 112: ...APPENDIX D 102 ISO Product Controller II and Hawkeye Operation Manual...
Page 116: ...APPENDIX E 106 ISO Product Controller II and Hawkeye Operation Manual...
Page 120: ...APPENDIX F 110 ISO Product Controller II and Hawkeye Operation Manual...
Page 128: ...APPENDIX G 118 ISO Product Controller II and Hawkeye Operation Manual...
Page 134: ...APPENDIX H 124 ISO Product Controller II and Hawkeye Operation Manual...